Iatrogenic atrial septal defect (iASD) represents one of the main access-related cardiac complications after trancatheter edge to edge (TEER) mitral valve repair with Mitraclip system. Transesophageal echocardiography (TEE) guiding supports a controlled and safe transseptal puncture. The rate of persistent iASD is 57, 50, and 25% after 1, 6, and 12 months post procedure. An elevated left atrial pressure after clip positioning correlates with iASD persistence. Its clinical impact is controversially discussed: Post-TEER iASD has been associated with right heart volume overload, as well as increased rates of heart failure (HF) hospitalization and death in some studies. In contrast, other studies have shown an association between post-TEER iASD and improved hemodynamics. In theory, creation of an iASD can decompress an overloaded left atrium, mitigating heart failure. Some studies have demonstrated that iASD closure can reduce significantly both right and left heart failure symptoms. We did a retrospective study enrolling in the period 2012-2022 twenty-one patients with severe mitral regurgitation treated with TEER. Our aim was to evaluate the clinical outcomes (symptoms, signs of heart failure, NYHA functional class) and echocardiographic parameters (PAPs, TAPSE, Right Atrium Area) in two group of patients: Group A underwent iASD closure during the TEER and Group B after one month following the TEER. At 1-month follow-up all patients with repaired mitral regurgitation showed an improvement in the NYHA class (from IV-III to II-I) and no need for re-hospitalization with no significant differences between two groups. In the Group A there were two adverse events during the recovery (2 major bleeding); while there were no adverse events in patients undergoing iASD closure after wise. There was 1 death in the first month after the procedure in group A, while there wasn't any in group B. Statistical analysis showed no significant differences in terms of NYHA class improvement in the two groups (p=0.91). We observed a greater reduction in PAPs in patients going to encounter intraprocedural DIA closure which was found to be statistically significant (p=0.01). Regarding TAPSE, there was a difference in terms of improvement which was found to be greater in the group A. However, this finding was not found to be statistically significant. We also assessed the right atrium area: in group A, we registered a mean preprocedural value of 28 cmq and a postprocedural value of 34 cmq; in group B the values were 20 cmq and 24 cmq, respectively, with a nonstatistically significant difference in terms of atrial enlargement post device placement. In conclusion, we can assume that the improvements in symptomatology are not closely related to iASD closure. However, it must considered that patients in group A had more unfavorable echocardiographic values before the procedure than those in group B, and probably, if we had not closed the iASD immediately during the procedure, these patients would have had worse symptomatology. Therefore, targeted patient selection is essential.
Mitral regurgitation (MR) is the second most frequent valve heart disease in Europe and its underlying mechanism primary-organic (due to disease of the mitral leaflets), or secondary-functional (where valve leaflets and chordae are structurally normal and MR results from alterations in left ventricle and left atrium geometry), determines the therapeutic approach. Transcatheter Edge-to-Edge Repair (TEER) with MitraClip implantation is a minimal-invasive treatment that according to 2021 ESC Guidelines should be considered (class of recomandation IIa) in selected symptomatic patients with severe MR despite optimal medical therapy, not eligible for surgery and fulfilling COAPT trial inclusion criteria, suggesting an increased chance of responding to treatment. Optimal valve morphology features for TEER are central pathology (second scallop), no leaflet calcifications, mitral valve area >4cm2, mobile length of posterior leaftel >10 mm, coaptation depth <11mm, normal leaflet strength and mobility, flail width <15 mm, flail gap <10 mm. TEER may be considered (class IIb) only in selected cases when the COAPT criteria are not fulfilled with the aim of improving symptoms and quality of life. MR occurs during systole, that at normal heart rates represents 30-50% of the cardiac cycle. As such, marked left atrial (LA) pressure elevation is present only transiently, representing less of a drive to development of secondary pulmonary hypertension compared to chronic LA pressure elevation seen in severe mitral stenosis. Anyway, in patients with severe MR echocardiography often reveals elevated systolic pulmonary artery pressure (PAPs) and MitraClip implantation usually is associated with a slight increase of the trans-mitral gradient with possible repercussions on pulmonary pressures. To better describe the effect of MitraClip implantation on pulmonary pressures and clinical outcomes we did a retrospective study enrolling in the period 2012-2022 thirty-six patients with severe mitral regurgitation treated with TEER. Compared to the last year presentation, we add eleven patients. The target was still to evaluate the clinical outcomes (symptoms, signs of heart failure, NYHA functional class) and the pulmonary pressures assessed by an echocardiographic examination before and after the intervention. At 6-month follow-up we observed in all patients with repaired mitral regurgitation an improvement in the NYHA class (from IV to II) without re-hospitalization. In addition we notice a more pronounced trend in the reduction of the mean sistolic pulmonary arterial pressure, estimated at around 2.86 mmHg ± 14 mmHg (p 0.24, 95% C.I. -7.69 to 1.94) with an unchanged left ventricle ejection fraction. Moreover, the echocardiographic exam showed a normalization of the S and D waves pattern in the pulmonary veins at the PW Doppler evaluation. These new data reinforced the idea that the clinical improvement and the reduction of dyspnea in these patients underwent TEER is related to a reduction of pressures in the pulmonary circulation regardless of the ejection fraction. This finding could be used as a tool that the cardiologist has to evaluate in the echocardiography lab to reveal a new mitral valve disfunction. Despite the addition of the new patients, the sample is still relatively small. However, considering the improvement of the results with the enlargement of the sample, the goal is to enroll additional patients to make the study even more meaningful.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.