Intervertebral instability of the lumbar spine is thought to be a possible pathomechanical mechanism underlying low back pain and sciatica and is often an important factor in determining surgical indication for spinal fusion and decompression. Instability of the lumbar spine, however, remains a controversial and poorly understood topic. At present, much controversy exists regarding the proper definition of the condition, the best diagnostic methods, and the most efficacious treatment approaches. Clinical presentation is not specific, and the relationship between radiologic evidence of instability and its symptoms is controversial. Because of its simplicity, low expense, and pervasive availability, functional flexion-extension radiography is the most thoroughly studied and the most widely used method in the imaging diagnosis of lumbar intervertebral instability. In this article, we provide an overview of the current concepts of vertebral instability, focusing on degenerative lumbar intervertebral instability, and review the different imaging modalities most indicated in diagnosing vertebral instability.
Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.