Despite the excellent success rates of the modern unicompartmental knee arthroplasty (UKA), results of knee replacement registries still shows a relatively high revision and failure rate for UKA, especially when compared with traditional total knee arthroplasty (TKA). Bearing dislocation continues to be advocated as the predominant mechanism of failure in mobile UKA, whereas polyethylene wear and aseptic loosening remains the main cause of failure of fixed UKA. Degeneration of the unreplaced compartments has been reported in both mobile and fixed designs. When the revision is required, most of failed UKAs are converted to TKAs. Surgical challenges of the UKA revision, and outcomes of UKA converted to TKA are still debated in literature.
AIMTo report the clinical and radiographic results of titanium elastic nail (TEN) in diaphyseal femoral fractures of children below age of six years.METHODSA retrospective analysis of 27 diaphyseal femoral fractures in children younger than six years treated with TEN between 2005 and 2015 was conducted. Patients were immobilized in a cast for 5 wk and the nails were removed from 6 to 12 wk after surgery. Twenty-four cases were clinically and radiographically re-evaluated using the Flynn’s scoring criteria, focusing on: Limb length discrepancy, rotational deformity, angulation, hip and knee range of motion (ROM), functional status, complications, and parent’s satisfaction.RESULTSSixteen males and eight females with a mean age of 3.2 years at the time of treatment were re-evaluated at an average follow-up of 58.9 mo. No cases of delayed union were observed. The mean limb lengthening was 0.3 cm. Four cases experienced limb lengthening greater than 1 cm and always minor than 2 cm. Twelve point five percent of the cases showed an angulation < 10°. Complete functional recovery (hip and knee ROM, ability to run and jump on the operated limb) occurred in 95.7% of cases. Complications included two cases of superficial infection of the TEN entry point, one case of refracture following a new trauma, and one TEN mobilization. According to the Flynn’s scoring criteria, excellent results were obtained in 79.2% of patients and satisfactory results in the remaining 20.8%, with an average parent’s satisfaction level of 9.1/10.CONCLUSIONTEN is as a safe, mini-invasive and surgeon-friendly technique and, considering specific inclusion criteria, it represents a useful and efficacy option for the treatment of diaphyseal femoral fractures even in patients younger than six years of age.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.