Interface infectious keratitis (IIK) is a novel corneal infection that may develop after any type of lamellar keratoplasty. Onset of infection occurs in the virtual space between the graft and the host where it may remain localised until spreading with possible risk of endophthalmitis. A literature review identified 42 cases of IIK. Thirty-one of them occurred after endothelial keratoplasty and 12 after deep anterior lamellar keratoplasty. Fungi in the form of Candida species were the most common microorganisms involved, with donor to host transmission of infection documented in the majority of cases. Donor rim cultures were useful to address the infectious microorganisms within few days after surgery. Due to the sequestered site of infection, medical treatment, using both topical and systemic antimicrobials drugs, was ineffective on halting the progression of the infection. Injection of antifungals, right at the graft–host interface, was reported successful in some cases. Spreading of the infection with development of endophthalmitis occurred in five cases after Descemet stripping automated endothelial keratoplasty with severe sight loss in three cases. Early excisional penetrating keratoplasty showed to be the treatment with the highest therapeutic efficacy, lowest rate of complications and greater visual outcomes.
The global spread of multidrug-resistant Gram-negative bacteria has led to the return of colistin for treating severe infections. Recently, different plasmid-mediated genes conferring resistance to this drug were described and reported worldwide. International committees (EUCAST/CLSI) reevaluated inconsistencies surrounding colistin antimicrobial susceptibility testing (AST), concluding that broth microdilution (BMD) should serve as the reference method for AST. The development of an accurate, reproducible commercial test based on BMD is therefore highly desirable. SensiTest Colistin (STC), a BMD-based compact 4-test panel containing the lyophilized antibiotic in 7 2-fold dilutions (0.25 to 16 μg/ml) was here compared with the EUCAST-CLSI standard reference method (BMD) and, for some isolates, with the automated Phoenix 100 system (PHX). A total of 353 bacterial strains were evaluated by two different laboratories; 137 isolates were resistant to colistin (19 were intrinsically resistant, 83 harbored the gene). Essential agreement (EA) between STC and BMD was obtained for 339 out of the 353 strains tested (96.0%). Overall categorical agreement was obtained for 349 out of the 353 strains analyzed (98.9%). Two major errors (MEs; 0.93%) and two very major errors (VMEs; 1.46%) were documented. STC appeared to be a simple but highly reliable test with good reproducibility even with panels stored at room temperature or at 35°C. Moreover, STC showed a good performance with strains carrying the gene, with a 98.8% EA. As the secondary endpoint of our study, VMEs for PHX were documented for 6 isolates (10%).
bMany studies demonstrate that delayed proper therapy in bloodstream infections caused by Staphylococcus aureus increases the mortality rate, emphasizing the need to shorten the turnaround time for positive blood cultures. Different techniques are currently available, from phenotypic methods to more complex tests such as matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF), real-time PCR (RT-PCR), and fluorescence in situ hybridization using peptide nucleic acid probes (PNA FISH). This study evaluated the performance of the Staphylococcus QuickFISH BC test (QFT), a novel FISH methodology, compared with the direct tube coagulase test (DTCT) on blood cultures exhibiting Gram-positive cocci in clusters. A total of 173 blood cultures collected from 128 different patients were analyzed using the DTCT, evaluated after both 4 and 24 h, and the QFT. A total of 179 isolates were identified using the Vitek2 system. Thirty-five out of 35 Staphylococcus aureus were correctly identified by the QFT (sensitivity ؍ 100%), with a specificity of 100% (no green fluorescence was detected for strains different from S. aureus). The DTCT was positive after 4 h for 28 out of the 35 samples (sensitivity ؍ 80%) and after 24 h for 31 out of the 35 samples (sensitivity ؍ 88.57%). Among the remaining 144 isolates, one was then identified as Corynebacterium striatum and two as Micrococcus luteus. QFT identified 139 out of the 141 coagulase-negative staphylococci (CoNS) (sensitivity ؍ 98.58%), showing again a specificity of 100% (no fluorescent red signals were detected for strains different from CoNS). We also discuss also the implementation process of this methodology in our setting, with particular emphasis on the workflow and the cost-effectiveness.
In this study we report the detection of the recently described mcr-4 gene in two human isolates of Salmonella enterica serovar Typhimurium. The strains were isolated from faecal samples of two Italian patients with gastroenteritis, collected in 2016. The identified mcr-4 genes (variant mcr-4.2) differed from the mcr-4 gene originally described in a Salmonella strain of swine origin from Italy. Salmonella species could represent a hidden reservoir for mcr genes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.