Pubmed, Embase, and Cochrane were systematically reviewed for available evidence on bariatric surgery in adolescents. Thirty-seven included studies evaluated the effect of laparoscopic adjustable gastric banding (LAGB), Roux-en-Y gastric bypass (RYGB), or laparoscopic sleeve gastrectomy (LSG) in patients ≤18 years old. Fifteen of 37 studies were prospective, including one RCT. Mean body mass index (BMI) loss after LAGB was 11.6 kg/m2 (95 % CI 9.8–13.4), versus 16.6 kg/m2 (95 % CI 13.4–19.8) after RYGB and 14.1 kg/m2 (95 % CI 10.8–17.5) after LSG. Two unrelated deaths were reported after 495 RYGB procedures. All three bariatric procedures result in substantial weight loss and improvement of comorbidity with an acceptable complication rate, indicating that surgical intervention is applicable in appropriately selected morbidly obese adolescents.
Background and Aims
To assess safety of the Exilis™ gastric electrical stimulation (GES) system and to investigate whether the settings can be adjusted for comfortable chronic use in subjects with morbid obesity. Gastric emptying and motility and meal intake were evaluated.
Method
In a multicenter, phase 1, open prospective cohort study, 20 morbidly obese subjects (17 female, mean BMI of 40.8 ± 0.7 kg/m2) were implanted with the Exilis™ system. Amplitude of the Exilis™ system was individually set during titration visits. Subjects underwent two blinded baseline test days (GES ON vs. OFF), after which long-term, monthly follow-up continued for up to 52 weeks.
Results
The procedure was safe, and electrical stimulation was well tolerated and comfortable in all subjects. No significant differences in gastric emptying halftime (203 ± 16 vs. 212 ± 14 min, p > 0.05), food intake (713 ± 68 vs. 799 ± 69 kcal, p > 0.05), insulin AUC (2448 ± 347 vs. 2186 ± 204, p > 0.05), and glucose AUC (41 ± 2 vs.41 ± 2, p > 0.05) were found between GES ON and OFF. At week 4, 13, and 26, a significant (p < 0.01) reduction in weight loss was observed but not at week 52. At this time point, the mean excess weight loss (EWL) was 14.2 ± 4.5%.
Conclusion
Gastric electrical stimulation with the Exilis™ system can be considered as safe. No significant effect on food intake, gastric emptying, or gastric motility was observed. The reduction in weight loss with Exilis™ GES was significant but short lasting. Further electrophysiological research is needed to gain more insight in optimal stimulation parameters and lead localization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.