Objective To compare the intraocular pressure (IOP) obtained by Goldmann applanation tonometer (GAT), correcting applanation tonometer surface (CATS) and biomechanically corrected IOP (bIOP) of Corvis ST tonometer (CVS); and to determine the effects of manifest refraction spherical equivalent (MRSE), central corneal thickness (CCT) and mean corneal curvature (Km) on the IOP measurements of corneal refractive patients. Methods This was a single-center, retrospective, cross-sectional study of 120 eyes of 64 patients from May 1, 2020 to June 1, 2021 who underwent laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK). The level of agreement between the three tonometers was evaluated, and correlation between parameters was calculated using Pearson correlation. Results Mean preoperative to postoperative IOP in LASIK and PRK was 15.1 ± 3 to 11.3 ± 2.1 and 14.4 ± 2.6 to 12.1 ± 3 using GAT, 16.4 ± 2.8 to 13.1 ± 2.3 and 15.9 ± 2.6 to 13.7 ± 3 using CATS and 14.8 ± 2.4 to 12.9 ± 1.5 and 14.2 ± 2.4 to 12.6 ± 1.9 using CVS-bIOP. Preoperative IOP correlation between each tonometer pair showed that the lowest mean difference was between GAT and CVS-bIOP (0.32 in LASIK, 0.15 in PRK). Preoperative to postoperative IOP correlation of each tonometer resulted in a difference of 3.77, 2.30 in GAT; 3.32, 2.28 in CATS and 1.88, 1.62 in CVS-bIOP in the LASIK and PRK groups, respectively. Percentage change in CCT and Km was not correlated while change in MRSE had a weak relationship with percentage change in CVS-bIOP. Conclusion Preoperatively, GAT and CVS-bIOP had the best agreement in IOP measurements. CATS recorded the highest IOP preoperatively and postoperatively. IOP decreased in the three tonometers after LASIK and PRK with GAT having the largest decrease. CVS-bIOP had the lowest change between preoperative and postoperative IOP measurements. Only percentage change in MRSE was correlated with percentage change in CVS-bIOP in the LASIK group.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.