BackgroundQuality control programs are necessary to maintain good clinical practice. Embryo grading has been described as one of the external quality assurance schemes. Although the evaluation of embryos is based on the assessment of morphological characteristics, considerable intra- and inter-observer variability has been described. In this multicentre study, the variability in the embryo evaluation has been evaluated using morphological characteristics on day 1, day 2 and day 3 of embryo development.MethodsFive embryologists of four different IVF centers participated in this study. Multilevel images of embryos were presented on a website at different time points to evaluate intra-and inter-observer agreement in the assessment of embryo morphology. The embryos were evaluated on day 1, day 2 and day 3 of their development and each embryologist had to decide if the embryo had to be transferred, cryopreserved or discarded.ResultsBoth intra-observer agreement and inter-observer agreement were good to excellent for the position of the pronuclei on day 1, the number of blastomeres on day 2 and day 3 and the clinical decision (transfer, cryopreservation, discard). For all other characteristics (size of pronuclei, presence of cytoplasomic halo, degree of fragmentation and size of blastomeres) the intra- and inter-observer agreement was moderate to very poor.ConclusionsMono- or multicentre quality control on embryo scoring by morphological assessment can easily be performed through the design of a simple website. In the future the website design can be adapted to generate statistical feedback upon scoring and can even include a training module.
Background: The aim of this study was to determine the intra-and inter-observer variability in the evaluation of embryo quality. Multilevel images of embryos on day 1, day 2 and day 3, were analysed using different morphological parameters.
Embryo selection is based on embryo developmental and morphological characteristics. Standard embryo evaluation has some disadvantages. New technology using multilevel images combined with a computer-assisted scoring system (CASS) has the potential to overcome these disadvantages. The aim of this study was to compare the value of a computer-assisted scoring system (CASS) versus a standard scoring system (SSS) in predicting implantation and live birth. This prospective study included 3185 embryos obtained during 502IVF/intracytoplasmic sperm injection cycles with single-embryo transfer on day 3. Embryos were evaluated with two scoring systems: SSS and CASS. Logistic regression analyses were performed using implantation and live birth as outcomes. According to multiple regression analysis, implantation was influenced by number and size of blastomeres on day 3 using CASS and by all embryo parameters on day 3 using SSS. Combined analysis of both scoring systems revealed that implantation was affected by number and size of blastomeres using CASS and by the degree of embryo fragmentation using SSS. Using live birth as outcome, only the number of blastomeres on day 3, evaluated by SSS and CASS, was predictive. Prediction of implantation and live birth may be superior using CASS when compared with SSS. Embryo selection is currently based on embryo developmental and morphological characteristics of an embryo using a standard scoring system. This evaluation system is limited by a number of disadvantages. New technology using multilevel images combined with a computer-assisted scoring system has the potential to overcome these disadvantages. The aim of this study was to compare the value of such computer-assisted scoring system versus a standard scoring system in predicting implantation and live birth rate. This study included 3185 embryos obtained during 502 IVF or intracytoplasmic sperm injection cycles with single-embryo transfer on day 3. All the embryos were evaluated with two types of scoring systems: a standard scoring system and a computer-assisted scoring system. According to the statistical analysis, the implantation of an embryo was influenced by the number and size of blastomeres on day 3 when evaluated with the computer-assisted scoring system, and by all embryo parameters on day 3 using the standard scoring system. Combined analysis of both scoring systems revealed that implantation was affected by number and size of blastomeres using the computer-assisted scoring system and by the degree of embryo fragmentation using the standard scoring system. Live birth was influenced by the number of blastomeres on day 3 evaluated by both scoring systems. Prediction of embryo implantation and live birth was superior using the computer-assisted scoring system. In conclusion, a computer-assisted scoring system may be superior to a standard scoring system in the prediction of implantation and live birth.
BackgroundThe success of in vitro fertilization techniques is defined by multiple factors including embryo culture conditions, related to the composition of the culture medium. In view of the lack of solid scientific data and in view of the current general belief that sequential media are superior to single media, the aim of this randomized study was to compare the embryo quality in two types of culture media.MethodsIn this study, the embryo quality on day 3 was measured as primary outcome. In total, 147 patients younger than 36 years treated with IVF/ICSI during the first or second cycle were included in this study. Embryos were randomly cultured in a sequential (group A) or a single medium (group B) to compare the embryo quality on day 1, day 2 and day 3. The embryo quality was compared in both groups using a Chi-square test with a significance level of 0.05.ResultsAt day 1, the percentage of embryos with a cytoplasmic halo was higher in group B (46%) than in group A (32%). At day 2, number of blastomeres, degree of fragmentation and the percentage of unequally sized blastomeres were higher in group B than in group A. At day 3, a higher percentage of embryos had a higher number of blastomeres and unequally sized blastomeres in group B. The number of good quality embryos (GQE) was comparable in both groups. The embryo utilization rate was higher in group B (56%) compared to group A (49%).ConclusionsAlthough, no significant difference in the number of GQE was found in both media, the utilization rate was significantly higher when the embryos were cultured in the single medium compared to the sequential medium. The results of this study have a possible positive effect on the cumulative cryo-augmented pregnancy rate.Trial registration numberNCT01094314
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.