The main horizontal well completion issues have been identified and addressed during the previous decades, resulting in wells with better performance, lower water production and higher recovery efficiencies. One of the most important issues has been inflow equalization, which is affected by reservoir heterogeneities and pressure losses in the completion (annulus and liner). Evaluations of the flow equalization, in sandstone and natural fracture reservoirs, along horizontal wells have shown the importance of this technique to improve reservoir management.Passive inflow control device (PICD) performance in producer and injector wells under different fluid properties (density and viscosity) and operational conditions will be presented to show the technical benefits of this technique as well as their improved recovery efficiencies when compared to non-PICD completions. The quantification of the benefits of this completion technique was performed using a fully integrated reservoir simulator where the PICD flow performance characteristic, well completion description (packers, blank pipe, gravel pack, annulus flow, etc.), and reservoir simulation are considered.Lessons learned and best practices regarding equipment selection and specification acquired during the last 10 years are summarized to define potential PICD applications in horizontal wells. Finally, the field experiences and numerical simulation results are analyzed to establish the best well completion strategy to fit specific reservoir conditions. SPE 124349 PICD Design CharacteristicsThe primary factor in maintaining a uniform influx is the ability of the device to resist erosion from fluid-borne particles that pass through the screen. Screens are not designed to prevent 100% blockage of all particles from the formation. During production, formation fines that are produced through the screen also pass through the PICD. These fines can and will erode a PICD over time if the fluid velocity is high enough and fines are in the flow stream. The rate of erosion will depend on the following factors: particle size, particle concentration, and fluid velocity. The first two factors are dependent on well conditions, while the third is dependent on PICD geometry and design.Currently, there are two major different types of PICD designs in the industry: orifice/nozzle-based (restrictive) and helical-channel/labyrinth pathway (frictional). They use two different methods to achieve a uniform inflow profile. The orifice-based PICD uses fluid constriction to generate a differential pressure across the device. This method essentially forces the fluid from a larger area down through small-diameter ports, creating a flow resistance. This overall change in pressure is what allows the PICD to function.The helical-channel ( Fig. 1) and labyrinth pathway PICDs, however, use surface friction to generate a similar pressure drop. The helical channel design is one or more flow channels that are wrapped around the basepipe of the screen. The labyrinth design uses a tortuous pathway to cre...
In long horizontal wells, oil production rate is typically affected by the reservoir heterogenities, heel to toe effect and mobility ratio. The resulting imbalanced production profile may cause early water or gas breakthrough into the wellbore. Once coning occurs, well fluid production may be severely decreased due to limited flow contribution from the toe or from reservoir areas with high flow resistance in the porous media. To eliminate this imbalance, passive inflow control devices (PICDs) are placed in each screen joint or inflow point to balance the production influx profile across the entire lateral length and compensate for permeability variation.PICD performance in producer (oil, gas, and high gas/oil ratio environments) wells under different operational conditions will be presented to show the technical benefits of this technique as well as their improved recovery efficiencies when compared to non-PICD completions. Fluid viscosity insensitivity of the PICD is critical to minimize preferential water flow whenever water breaks through into the well. The quantification of the benefits of this completion technique was performed using a fully integrated reservoir simulator where the PICD flow performance characteristic (as a function of fluid properties and geometry), well completion description (packers, blank pipe, gravel pack, annulus flow, etc.) and reservoir simulation are considered. Shutting off whole sections that have unacceptably high water and/or gas production using the latest PICD feature is also modeled to show improved recovery performance. This paper details the development of the latest-generation PICD design concept. Because these PICDs are permanent downhole components, their long-term reliability is imperative, and these new developments will improve their resistance to erosion and their ability to effectively balance inflow. Computational flow dynamics (CFD) analysis was used extensively to characterize the new design, under liquid and gas conditions, along with actual full-scale flow testing.
In long horizontal wells, production rate is typically higher at the heel of the well than at the toe. The resulting imbalanced production profile may cause early water or gas breakthrough into the wellbore. Once coning occurs, well production may be severely decreased due to limited flow contribution from the toe. To eliminate this imbalance, inflow control devices (ICDs) are placed in each screen joint to balance the production influx profile across the entire lateral length and to compensate for permeability variation. Pressure drop in an ICD is created through either restriction or friction mechanisms. Restriction mechanisms rely on a contraction of the fluid flow path to generate an instantaneous pressure drop, resulting in higher velocities, and are thus more prone to long-term erosion damage as well as plugging during mud flowback. A restriction device, however, is less sensitive to viscosity properties of the fluid. A frictional device, which creates a pressure drop over a distributed length, is less likely to erode due to lower fluid velocities, but is more sensitive to viscosity changes. Viscosity insensitivity is desired to minimize preferential water flow whenever water breaks through into the well. This paper will detail the development of a new hybrid design concept that uses the best features of the restricting and friction designs, while minimizing the less desirable characteristics. Because these ICDs are permanent downhole components, their long-term reliability is imperative, and these new developments will improve their resistance to erosion and their ability to effectively balance inflow. Conceptual fluid dynamics analysis was used extensively to characterize the new design, along with actual full-scale flow testing. Introduction The purpose of inflow control devices (ICDs) is to effectively balance well production throughout the entire operational life of the completion to optimize hydrocarbon recovery. Since a typical well with ICDs can be in production from 5 to >20 years, the long-term reliability of such a device is crucial to the well's overall success. The significant factor in the reliability of an ICD is its ability to maintain a uniform influx over the well life. If an ICD is not able to maintain a uniform flux rate, increased localized production rates will occur and the well will become unbalanced. This will render the ICD ineffective, leading to premature water and/or gas breakthrough and possible loss of sand control. At some stage in a well's life, water may break through into the wellbore in certain sections due to heterogeneity of the formation and/or vertical fractures. Ideally, once this occurs, flow contribution from these water-producing zones should not be greater than the oil-producing sections. In production wells with higher-viscosity oil (>10 cp.), ICD type selection becomes a more critical factor due to the larger difference in viscosity between the oil and produced water. The pressure reduction mechanism in an ICD in this situation must have the lowest sensitivity to viscosity to maintain an even flow profile across the entire lateral wellbore. A restrictive-type ICD thus will provide best results in this regard due to its lower sensitivity to viscosity. This type of ICD however, has a greater potential for long-term erosion and lower plugging resistance. The ideal solution is to provide the lower viscosity sensitivity of the restrictive device with the lower erosion and higher plugging resistance of the frictional design. This means using the restrictive pressure loss mechanism while limiting the fluid velocity through the device below the critical level which will cause erosion. Limiting the fluid velocity also can result in increased minimum flow area if configured efficiently.
TX 75083-3836, U.S.A., fax +1-972-952-9435. AbstractIn long horizontal wells, production rate is typically higher at the heel than at the toe. The resulting imbalanced production profile may cause early water or gas breakthrough into the wellbore. Once coning occurs, well production may be severely decreased due to limited flow contribution from the toe. To eliminate this imbalance, inflow control devices (ICDs) are placed in each screen joint to balance the production influx profile across the entire lateral length and compensate for permeability variation. Passive ICDs should be designed to control the influx without the need for intervention.There are two basic pressure drop mechanisms used currently in ICDs, restriction or friction. Restriction mechanisms rely on a contraction of the fluid flow path to generate an instantaneous pressure drop across the device. A frictional device creates a pressure drop due to fluid flow along the length of a channel or tube.There is an industry misconception that all ICDs will create a uniform influx. The reality is that none of these mechanisms alone meets the ideal requirements of an ICD designed for the life of the well: high resistance to plugging, mud flowback assurance, high resistance to erosion and high viscosity insensitivity. This paper will detail the development of a new hybrid design that incorporates all the positive features necessary to effectively produce a well from startup, peak production, through eventual water onset and beyond. Available in standard or field-adjustable versions, this unique design maximizes flow areas to reduce velocities and increase erosion resistance. Fullscale performance testing validates that the hybrid design offers the highest level of viscosity insensitivity available. Because ICDs are permanent downhole components, their long-term reliability is imperative, and these new developments will improve their performance and ability to effectively balance inflow for the life of the well.
To address the need for better understanding of multiphase fluid flow behavior through passive inflow control devices (PICDs), two-phase (oil-water) full-scale flow loop testing on helical and a new ICD design, "Hybrid" has been completed. The primary testing objective was to generate a comprehensive two-phase (oil-water) data set of flow performance curves for the helical ICD and the hybrid ICD. The test included a broad range of flow tests with varying viscosities, water cuts and pressures. The results are presented in an innovative manner using isobaric plots (isobars lines with trend lines for each viscosity value) and Reynolds number vs. Flow Coefficient plots, which can be used to easily compare different ICD performances. Test results confirm that for oil-water flow, a viscosity break point for the helical ICD occurs at 2 centipoise (cP) of medium oil. Below this break point the helical ICD does not promote water production in two-phase flow. Above this viscosity break point, the helical ICD exhibits a physical phenomenon where, at water cuts above 30%, the total flow increases at any given pressure drop promoting water flow. With regards to two-phase oil-water fluid flow, the hybrid ICD performs independently of viscosity for the range tested (up to 200 cP - maximum flow viscosity tested at the lab).The hybrid ICD consistently creates more resistance to water flow than to oil flow, causing total flow to gradually decrease at constant pressure as water cut increases. This effect was more apparent at higher pressure regimes. The functional break point of the hybrid ICD is determined to be above 200 cP. Introduction A comprehensive two-phase (oil-water) data set of flow performance curves for the helix inflow control devices (ICDs) and hybrid ICDs was conducted through extensive laboratory testing to identify the threshold viscosity, and to quantify single and multiphase model validity. These test results confirm that the threshold viscosity is 2 centipoise (cP). At viscosities greater than 2 cP, the test results confirm previously published findings that the helix design exhibits preferential production of water for a given pressure drop in a two-phase flow. Additionally, results verify that the helix ICD behavior exhibits correlation to the single phase model but requires a correction due to non-constant flow coefficient, and does not exhibit correlation when the fluids are multiphase, especially at higher viscosities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.