Background The utility of heated and humidified high-flow nasal oxygen (HFNO) for severe COVID-19-related hypoxaemic respiratory failure (HRF), particularly in s``ettings with limited access to intensive care unit (ICU) resources, remains unclear, and predictors of outcome have been poorly studied. Methods We included consecutive patients with COVID-19-related HRF treated with HFNO at two tertiary hospitals in Cape Town, South Africa. The primary outcome was the proportion of patients who were successfully weaned from HFNO, whilst failure comprised intubation or death on HFNO. Findings The median (IQR) arterial oxygen partial pressure to fraction inspired oxygen ratio (P a O2/FiO 2 ) was 68 (54–92) in 293 enroled patients. Of these, 137/293 (47%) of patients [P a O2/FiO 2 76 (63–93)] were successfully weaned from HFNO. The median duration of HFNO was 6 (3–9) in those successfully treated versus 2 (1–5) days in those who failed ( p <0.001). A higher ratio of oxygen saturation/FiO2 to respiratory rate within 6 h (ROX-6 score) after HFNO commencement was associated with HFNO success (ROX-6; AHR 0.43, 0.31–0.60), as was use of steroids (AHR 0.35, 95%CI 0.19–0.64). A ROX-6 score of ≥3.7 was 80% predictive of successful weaning whilst ROX-6 ≤ 2.2 was 74% predictive of failure. In total, 139 patents (52%) survived to hospital discharge, whilst mortality amongst HFNO failures with outcomes was 129/140 (92%). Interpretation In a resource-constrained setting, HFNO for severe COVID-19 HRF is feasible and more almost half of those who receive it can be successfully weaned without the need for mechanical ventilation.
Background: The utility of heated and humidified high-flow nasal oxygen (HFNO) for severe COVID-19related hypoxaemic respiratory failure (HRF), particularly in settings with limited access to intensive care unit (ICU) resources, remains unclear, and predictors of outcome have been poorly studied. Methods: We included consecutive patients with COVID-19-related HRF treated with HFNO at two tertiary hospitals in Cape Town, South Africa. The primary outcome was the proportion of patients who were successfully weaned from HFNO, whilst failure comprised intubation or death on HFNO. Findings: The median (IQR) arterial oxygen partial pressure to fraction inspired oxygen ratio (P a O2/FiO 2 ) was 68 (54À92) in 293 enroled patients. Of these, 137/293 (47%) of patients [P a O2/FiO 2 76 (63À93)] were successfully weaned from HFNO. The median duration of HFNO was 6 (3À9) in those successfully treated versus 2 (1À5) days in those who failed (p<0.001). A higher ratio of oxygen saturation/FiO2 to respiratory rate within 6 h (ROX-6 score) after HFNO commencement was associated with HFNO success (ROX-6; AHR 0.43, 0.31À0.60), as was use of steroids (AHR 0.35, 95%CI 0.19À0.64). A ROX-6 score of 3.7 was 80% predictive of successful weaning whilst ROX-6 2.2 was 74% predictive of failure. In total, 139 patents (52%) survived to hospital discharge, whilst mortality amongst HFNO failures with outcomes was 129/140 (92%). Interpretation: In a resource-constrained setting, HFNO for severe COVID-19 HRF is feasible and more almost half of those who receive it can be successfully weaned without the need for mechanical ventilation.
Mycobacterium tuberculosis (MTB) is an under-recognised cause of genitourinary disease. IgA nephropathy (IgAN), a leading cause of glomerulonephritis worldwide, has been described as a rare consequence of disseminated MTB infection. In this case report, we present the first case of MTB associated IgAN in Africa. Finding IgAN on kidney biopsy in an MTB endemic area should prompt a thorough investigation for MTB to increase the chance of remission of IgAN and prevent inappropriate use of immunosuppression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.