Significant improvement in hand function could be achieved with constraint-induced movement therapy in subacute stroke patients, which was maintained up to 12 week follow-up.
The Green and O'Brien scoring system correlated most strongly with the DASH score. Radiological scoring (reflecting anatomical deformity) was not significantly correlated with functional outcome. While subjective parameters "pain" and "function" are influenced by psychosocial factors and thus highly variable, it is paramount to include subjective tools in outcome assessment in future studies on wrist fractures.
Dynamic hip screw (DHS) is a well-established conventional implant for treating intertrochanteric fracture. However, revision surgery sometimes still occurs due to the cutting out of implants. A helical blade instead of threaded screw (DHS blade) was designed to improve the fixation power of the osteoporotic intertrochanteric fracture. In this study, the biomechanical properties of DHS blade compared to the conventional DHS were evaluated using an unstable AO/OTA 31-A2 intertrochanteric fracture model. Fifty synthetic proximal femoral bone models with such configuration were fixed with DHS and DHS blade in five different positions: centre-centre (CC), superior-centre (SC), inferior-center (IC), centre-anterior (CA), and centre-posterior (CP). All models had undergone mechanical compression test, and the vertical and rotational displacements were recorded. The results showed that DHS blade had less vertical or rotational displacement than the conventional DHS in CC, CA, and IC positions. The greatest vertical and rotational displacements were found at CP position in both groups. Overall speaking, DHS blade was superior in resisting vertical or rotational displacement in comparison to conventional DHS, and the centre-posterior position had the poorest performance in both groups.
The 30-day and one-year mortality rates were 5% and 20%, respectively. At the one-year follow-up, 81 patients were available, and all fractures had healed without varus deformity. The mean tip-apex distance was 14.1 (range, 5.7-31.1; SD, 4.3) mm. The mean femoral shortening was 4.9 (range, 0-20.2; SD, 4.8) mm. The mean Parker score decreased to 3.8 at one-year follow-up from 5.9 before injury (p<0.001). There was one loss of fixation secondary to a non-traumatic subcapital fracture at 3 months, for which a bipolar hemiarthroplasty was performed. CONCLUSION; The DHS blade system is effective in treating AO/OTA 31-A1 and 31-A2 intertrochanteric hip fractures and results in a low complication rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.