Continuous wave (cw) diode lasers are increasingly being used as light sources in the visible and near-IR regions of the spectrum for cavity ringdown spectroscopy (CRDS) and cavity enhanced absorption spectroscopy (CEAS); the latter technique is also widely known as integrated cavity output spectroscopy (ICOS). The very high sensitivities to weak absorptions that are possible with cw CRDS and CEAS, coupled with the quantitative nature of the absorption measurements, are enabling a rapidly expanding range of applications. We review the benefits and practical implementation of these techniques; methods of data analysis for extraction of quantitative absorption data; the sensitivities of cw CRDS and CEAS, and how they might be optimised; and applications of cw CRDS and CEAS in molecular spectroscopy, atmospheric chemistry, plasma and flame chemistry, analytical science, and medical diagnosis via breath analysis. The development of CRDS and CEAS techniques exploiting cw diode lasers and, very recently, high luminosity light-emitting diodes, has stimulated a wealth of highsensitivity measurements. Highlights include quantitative measurement of various ultra-trace gases such as: NO 3 , NO 2 and ethene in ambient air samples; CO 2 isotopologues, ethane and other organic compounds in human breath samples; and excited electronic states of N 2 and O 2 in plasmas and discharges. Exciting developments include wavelength extension into the mid-IR and UV regions, and use of novel locked-cavity techniques to increase data acquisition rates and sensitivities.
Detection and analysis of volatile compounds in exhaled breath represents an attractive tool for monitoring the metabolic status of a patient and disease diagnosis, since it is non-invasive and fast. Numerous studies have already demonstrated the benefit of breath analysis in clinical settings/applications and encouraged multidisciplinary research to reveal new insights regarding the origins, pathways, and pathophysiological roles of breath components. Many breath analysis methods are currently available to help explore these directions, ranging from mass spectrometry to laser-based spectroscopy and sensor arrays. This review presents an update of the current status of optical methods, using near and mid-infrared sources, for clinical breath gas analysis over the last decade and describes recent technological developments and their applications. The review includes: tunable diode laser absorption spectroscopy, cavity ring-down spectroscopy, integrated cavity output spectroscopy, cavity-enhanced absorption spectroscopy, photoacoustic spectroscopy, quartz-enhanced photoacoustic spectroscopy, and optical frequency comb spectroscopy. A SWOT analysis (strengths, weaknesses, opportunities, and threats) is presented that describes the laser-based techniques within the clinical framework of breath research and their appealing features for clinical use.
A recent review (Ashfold et al., Phys. Chem. Chem. Phys., 2010, 12, 1218) highlighted the important role of dissociative excited states formed by electron promotion to σ* orbitals in establishing the photochemistry of many molecular hydrides. Here we extend such considerations to molecular halides, with a particular focus on iodobenzene. Two experimental techniques (velocity mapped ion imaging (VMI) and time resolved infrared (IR) diode laser absorption) and electronic structure calculations have been employed in a comprehensive study of the near ultraviolet (UV) photodissociation of gas phase iodobenzene molecules. The VMI studies yield the speeds and angular distributions of the I((2)P(3/2)) and I*((2)P(1/2)) photofragments formed by photolysis in the wavelength range 330 ≥λ≥ 206 nm. Four distinct dissociation channels are observed for the I((2)P(3/2)) atom products, and a further three channels for the I*((2)P(1/2)) fragments. The phenyl (Ph) radical partners formed via one particular I* product channel following excitation at wavelengths 305 ≥λ≥ 250 nm are distributed over a sufficiently select sub-set of vibrational (v) states that the images allow resolution of specific I* + Ph(v) channels, identification of the active product mode (ν(10), an in-plane ring breathing mode), and a refined determination of D(0)(Ph-I) = 23,390 ± 50 cm(-1). The time-resolved IR absorption studies allow determination of the spin-orbit branching ratio in the iodine atom products formed at λ = 248 nm (ϕ(I*) = [I*]/([I] + [I*]) = 0.28 ± 0.04) and at 266 nm (ϕ(I*) = 0.32 ± 0.05). The complementary high-level, spin-orbit resolved ab initio calculations of sections (along the C-I bond coordinate) through the ground and first 19 excited state potential energy surfaces (PESs) reveal numerous excited states in the energy range of current interest. Except at the very shortest wavelength, however, all of the observed I and I* products display limiting or near limiting parallel recoil anisotropy. This encourages discussion of the fragmentation dynamics in terms of excitation to states of A(1) total symmetry and dissociation on the 2A(1) and 4A(1) (σ* ← n/π) PESs to yield, respectively, I and I* products, or via non-adiabatic coupling to other σ* ← n/π PESs that correlate to these respective limits. Similarities (and differences) with the available UV photochemical data for the other aryl halides, and with the simpler (and more thoroughly studied) iodides HI and CH(3)I, are summarised.
Laser absorption spectroscopy of respired gas offers new opportunities for monitoring critically ill patients.
Inhomogeneity in the lung impairs gas exchange and can be an early marker of lung disease. We hypothesized that highly precise measurements of gas exchange contain sufficient information to quantify many aspects of the inhomogeneity noninvasively. Our aim was to explore whether one parameterization of lung inhomogeneity could both fit such data and provide reliable parameter estimates. A mathematical model of gas exchange in an inhomogeneous lung was developed, containing inhomogeneity parameters for compliance, vascular conductance, and dead space, all relative to lung volume. Inputs were respiratory flow, cardiac output, and the inspiratory and pulmonary arterial gas compositions. Outputs were expiratory and pulmonary venous gas compositions. All values were specified every 10 ms. Some parameters were set to physiologically plausible values. To estimate the remaining unknown parameters and inputs, the model was embedded within a nonlinear estimation routine to minimize the deviations between model and data for CO, O, and N flows during expiration. Three groups, each of six individuals, were studied: young (20-30 yr); old (70-80 yr); and patients with mild to moderate chronic obstructive pulmonary disease (COPD). Each participant undertook a 15-min measurement protocol six times. For all parameters reflecting inhomogeneity, highly significant differences were found between the three participant groups ( P < 0.001, ANOVA). Intraclass correlation coefficients were 0.96, 0.99, and 0.94 for the parameters reflecting inhomogeneity in deadspace, compliance, and vascular conductance, respectively. We conclude that, for the particular participants selected, highly repeatable estimates for parameters reflecting inhomogeneity could be obtained from noninvasive measurements of respiratory gas exchange. NEW & NOTEWORTHY This study describes a new method, based on highly precise measures of gas exchange, that quantifies three distributions that are intrinsic to the lung. These distributions represent three fundamentally different types of inhomogeneity that together give rise to ventilation-perfusion mismatch and result in impaired gas exchange. The measurement technique has potentially broad clinical applicability because it is simple for both patient and operator, it does not involve ionizing radiation, and it is completely noninvasive.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.