Ischemic colitis is a rare, life-threatening, consequence of mesenteric arteriovenous malformations. Ischemia ensues from a steal phenomenon through shunting, and may be compounded by the resulting portal hypertension. Computed tomographic angiography is the most common first-line test because it is quick, non-invasive, and allows for accurate anatomic characterization. Also, high-resolution three-dimensional images can be created for treatment planning. Magnetic resonance angiography is similarly sensitive for vascular mapping. Conventional angiography remains the gold standard for diagnosis and also allows for therapeutic endovascular embolization. Our patient underwent testing using all three of these modalities. We present the first reported case of this entity in a patient with a vascular connective tissue disorder.
The purpose of this study was to determine the value of follow-up barium esophogram in diagnosing esophageal injury or leak if the initial water-soluble contrast examination of the esophagus is normal. An institutional review board (IRB)-approved retrospective review of all pediatric patients less than 18 years old referred to the radiology department for evaluation of esophageal injury or leak was performed for a 9-year period from 2005 to 2014. The majority of patients had unexplained pneumomediastinum, chest trauma (gunshot or puncture wound), or foreign body ingestion as the reason for the referral. Forty-nine patients (age range 10 days to 17 years) underwent an initial water-soluble esophogram immediately followed by a barium esophogram. Forty-six studies were negative on both water-soluble contrast and barium studies. Two studies were both positive on the initial water-soluble contrast and subsequent barium studies. A single study showed the esophageal leak only in the water-soluble study, with the follow-up barium exam being normal. The result of this study indicates that a single-contrast water-soluble esophogram alone is sensitive in the diagnosis of esophageal injury or leak. It has a 100 % sensitivity and negative predictive value. A follow-up barium esophogram only increases the study time and radiation dose to the patient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.