In this paper, we describe the design and performance of the first integrated-circuit microsensor developed for daily ingestion by patients. The ingestible sensor is a device that allows patients, families, and physicians to measure medication ingestion and adherence patterns in real time, relate pharmaceutical compliance to important physiologic metrics, and take appropriate action in response to a patient's adherence pattern and specific health metrics. The design and theory of operation of the device are presented, along with key in-vitro and in-vivo performance results. The chemical, toxicological, mechanical, and electrical safety tests performed to establish the device's safety profile are described in detail. Finally, aggregate results from multiple clinical trials involving 412 patients and 5656 days of system usage are presented to demonstrate the device's reliability and performance as part of an overall digital health feedback system.
Poor adherence to tuberculosis (TB) treatment hinders the individual’s recovery and threatens public health. Currently, directly observed therapy (DOT) is the standard of care; however, high sustaining costs limit its availability, creating a need for more practical adherence confirmation methods. Techniques such as video monitoring and devices to time-register the opening of pill bottles are unable to confirm actual medication ingestions. A novel approach developed by Proteus Digital Health, Inc. consists of an ingestible sensor and an on-body wearable sensor; together, they electronically confirm unique ingestions and record the date/time of the ingestion. A feasibility study using an early prototype was conducted in active TB patients to determine the system’s accuracy and safety in confirming co-ingestion of TB medications with sensors. Thirty patients completed 10 DOT visits and 1,080 co-ingestion events; the system showed 95.0% (95% CI 93.5–96.2%) positive detection accuracy, defined as the number of detected sensors divided by the number of transmission capable sensors administered. The specificity was 99.7% [95% CI 99.2–99.9%] based on three false signals recorded by receivers. The system’s identification accuracy, defined as the number of correctly identified ingestible sensors divided by the number of sensors detected, was 100%. Of 11 adverse events, four were deemed related or possibly related to the device; three mild skin rashes and one complaint of nausea. The system’s positive detection accuracy was not affected by the subjects’ Body Mass Index (p = 0.7309). Study results suggest the system is capable of correctly identifying ingestible sensors with high accuracy, poses a low risk to users, and may have high patient acceptance. The system has the potential to confirm medication specific treatment compliance on a dose-by-dose basis. When coupled with mobile technology, the system could allow wirelessly observed therapy (WOT) for monitoring TB treatment as a replacement for DOT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.