Background: This systematic review and meta-analysis compares long-term outcomes follow-up data comparing drug-eluting balloons (DEBs) and drug-eluting stents (DESs) in interventional treatment of small coronary artery disease (<3 mm). Methods: A systematic review was undertaken along with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The primary outcome was 1–3-year performance of DEB versus DES in major adverse cardiac events. Secondary outcomes include all-cause mortality, MI, cardiac death, vessel thrombosis, major bleeding, target vessel revascularisation and target lesion revascularisation. Two independent reviewers extracted data. All outcomes used the Mantel–Haenszel and random effects models. ORs are presented with a 95% CI. Results: Of 4,661 articles, four randomised control trials were included (1,414 patients). DEBs demonstrated reduced rates of non-fatal MI at 1 year (OR 0.44; 95% CI [0.2–0.94]), and BASKET-SMALL 2 reported a significant reduction in 2-year bleeding rates (OR 0.3; 95% CI [0.1–0.91]). There was no significant difference in all other outcomes. Conclusion: Long-term follow-up of DEB and DES use in small coronary arteries demonstrates DEBs be comparable with DESs in all outcomes at 1, 2 and 3 years of follow-up. A significant reduction was found in rates of non-fatal MI at 1 year in the DEB arm, and a reduction in major bleeding episodes at 2 years in the BASKET-SMALL 2 trial. These data highlight the potential long-term utility of novel DEBs in small coronary artery disease revascularisation.
Background Obstructive sleep apnoea (OSA) is present in 40-80% of patients with cardiovascular morbidity and is associated with adverse effects on cardiovascular health. Continuous positive airway pressure (CPAP) maintains airway patency during sleep and is hypothesised to improve cardiac function. In the present study, we report on the impact of 12 weeks of CPAP and improvements in echocardiographic parameters of the right ventricle (RV). Methods Nineteen newly diagnosed patients with OSA and a respiratory disturbance index (RDI) greater than 10 were enrolled. Echocardiography was performed before treatment and with a follow-up assessment after 12 weeks of CPAP. Echocardiographic and Doppler measurements were made following the American Society for Echocardiography guidelines. The primary outcome was isovolumetric acceleration (IVA). Secondary outcomes include tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), RV % strain, TEI index and RV dimension index (RVDI). Results There significant improvement in isovolumetric acceleration of 0.5ms2 (P=0.0012 (95% CI -0.72, -0.20)) and significant improvement of 2.05mm in TAPSE (p=0.0379 (95% CI -3.98 - -0.13). There was a trend to improvements in FAC, RV % strain, TEI index or RVDI with twelve weeks of CPAP therapy. Conclusion. The present study highlights significant increase in TAPSE and IVA with 12 weeks of CPAP treatment and a trend to improvement in FAC, RVDI and RV % strain. These data indicate favourable characteristics on both load dependent and load independent markers of RV function with CPAP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.