Ultrasound is unlikely to increase the accuracy of injections into an unseptated FDC. It may aid in injection of a septated FDC; however, that remains to be statistically demonstrated.
The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.
Background:
Controversy exists with regard to the amount of fracture displacement that warrants surgical fixation of medial epicondyle fractures. Inaccurate determination of degree of displacement on plain radiographs may account for the disputed management. Recently, a novel distal humerus axial radiograph technique has been developed to improve the accuracy of radiographs. The purposes of the study are 2-fold; to identify the anatomic orientation of the medial elbow epicondyle physis in children and to compare the accuracy of determining fracture displacement between axial radiographs and standard anterior-posterior (AP) radiographs in a cadaveric medial epicondyle fracture model.
Methods:
Twelve pediatric elbow computed tomographic scans and 19 pediatric elbow magnetic resonance imaging scans were analyzed for the orientation of the medial elbow physis. After determining the correct orientation, 15 adult cadaveric medial epicondyle fracture models were created at displacements of 2, 5, 10 mm, and maximum displacement with elbow at 90 degrees of flexion. A linear mixed model regression analysis was used to compare displacement based on the axial versus the AP radiographic methods.
Results:
The medial epicondyle physis was found to be a posterior structure angled distally at ~36 degrees (range, 10.7 to 49.6) and angled posteriorly at 45 degrees (range, 32.2 to 59). The AP radiograph significantly underestimated displacement relative to the axial radiograph at 5 mm [mean difference, −1.6; 95% confidence interval (CI), −2.9 to −0.3], at 10 mm (mean difference, −4.5; 95% CI, −5.8 to −3.2 mm), and at maximal displacement (mean, 15 mm; range, 13 to 20 mm) (mean difference, −7.1; 95% CI, −8.3 to −5.8).
Conclusions:
The medial epicondyle physis of the distal humerus is a posterior structure angled distally and posteriorly. When displacement was >5 mm, the distal humerus axial radiograph technique was significantly more accurate than the AP radiograph technique at determining actual fracture displacement in our adult cadaveric fracture models. Therefore, we recommend clinicians to include the axial radiograph view during the evaluation of patients with medial epicondyle fractures.
Clinical Relevance:
This study provides further insight into the location and orientation of the medial humeral epicondyle physis, and further supports the improved accuracy of the distal humerus axial radiograph at detecting displacement in medial epicondyle fractures.
Surgeons undergoing additional hand fellowship training may show improved outcomes in the surgical treatment of carpal tunnel syndrome. However, no effect was seen on nerve injury or recurrence of symptoms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.