Measurements of the particle size distribution at the outlets of six coal-fired utility boilers showed a peak at a particle diameter near 0.1 micrometer. This submicrometer mode appears to be a general feature of coal combustion that results from a volatilization-condensation process in the boiler. At the boilers tested, the submicrometer mode contained 0.2 to 2.2 percent of the total fly ash mass. The importance of this mode is greater than its small quantity suggests because particles in the submicrometer size range are often much more difficult to collect with conventional particulate control devices than larger particles. Thus, the submicrometer mode may significantly influence the design and selection of future power plant emission controls. The particle mass in the submicrometer mode was correlated with the nitric oxide concentration in the flue gas. This correlation suggests that control of nitric oxide by modification of the combustion conditions may reduce the generation and emission of submicrometer particles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.