Common peroneal nerve palsy has been reported to be the most frequent lower extremity palsy characterized by a supinated equinovarus foot deformity and foot drop. Dynamic tendon transposition represents the gold standard for surgical restoration of dorsiflexion of a permanently paralyzed foot. Between 1998 and 2005, we operated on a selected series of 16 patients with traumatic complete common peroneal nerve palsy. In all cases, we performed a double tendon transfer through the interosseous membrane. The posterior tibialis tendon was transferred to the tibialis anterior rerouted through a new insertion on the third cuneiform and the flexor digitorum longus was transferred to the extensor digitorum longus and extensor hallucis longus tendons. All 16 patients were reviewed at a minimum followup of 24 months (mean, 65 months; range, 24-114 months). The results were assessed using the Stanmore system questionnaire and were classified as excellent in eight, good in five, fair in two, and poor in one. Postoperative static and dynamic baropodometric evaluations also were performed. The proposed procedure, which provides an appropriate direction of pull with adequate length and fixation, is a reliable new method to restore balanced foot dorsiflexion correcting the foot and digit drop and producing a normal gait without the use of orthoses.
Purpose The aim of this study was to evaluate the efficacy of revision total knee arthroplasty (TKA) with cementless metaphyseal sleeves without stems either in the femoral or tibial side or in both. Methods In this retrospective study, 51 patients (51 knees) operated in the period 2010 to 2015 met the above-mentioned criteria and were invited to a medical examination including X-rays. Forty-six were available for the study. Mean follow-up was 37 months. Knee Society score (KSS) (objective knee score), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and range of motion (ROM) were used as outcome scores and compared with baseline values. X-rays were also examined and compared with postoperative exams to evaluate the presence of loosening, radiolucent lines, and bone ingrowth. Satisfaction of the patients was also investigated using a linear scale from 1 to 10. Results KSS improved from 39 to 77 ( p < 0.01); WOMAC score improved from 76 to 41 ( p < 0.01). Twenty-four (52%) patients were satisfied, 15 (32%) were partially satisfied, and 7 (16%) were unsatisfied. ROM improved from 93 to 96 degrees (nonsignificant difference). X-rays showed no loosening of the implants, radiolucent lines in 4 patients (3 of them were asymptomatic) and bone ingrowth in 43 out of 46 patients. Conclusion In this short-term retrospective study, the use of sleeves without stem was a safe and effective procedure in revision TKA. We found a significant improvement in clinical results compared with baseline values and no signs of implant loosening. Level of Evidence Level IV, therapeutic case series.
Purpose The aim of this study was to evaluate the efficacy in terms of clinical results and radiographic findings of using metaphyseal sleeves in revision total knee arthroplasty (TKA), and to check if the use of sleeves without stems did not impair such results. Methods In this retrospective study, 141 patients (143 knees) operated in the period 2008 to 2015 met the above-mentioned criteria and were invited to a medical examination including X-rays. A total of 121 knees were available for the study (44 in the group without stems and 77 in the group with stems). Mean follow-up was 63 months for the stemless group and 89 for the group with stems. Knee Society Score (KSS) (objective knee score) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were used as outcome scores and compared with baseline values, range of motion (ROM) was also compared with preop value and X-rays were also examined and compared with immediate postop X-rays to check signs of loosening and radiolucent lines, if any, and bone ingrowth. Satisfaction of the patients was also investigated using a linear scale from 1 to 10. Results KSS improved from 34 to 81 postop (39 to 81 in the stemless group) (p < 0.01), while WOMAC from 82% preop to 39% postop (76 to 37% in the stemless group) (p < 0.01). Forty-six patients were satisfied, 20 partially satisfied, and 11 unsatisfied (respectively 25–14–5 in the stemless group). ROM improved from 89 degrees preop to 99 degrees postop (93 to 98 degrees in the stemless group). X-rays showed no loosening of the implant, radiolucent lines in 8 patients, and bone ingrowth in 113 out of 121 patients. Conclusion In this midterm follow-up study, we found a significant improvement in clinical results compared with preop values. We found no difference between the two groups (with and without stems) thus suggesting that the use of stemless sleeves does not impair results in revision TKA. Level of Evidence Therapeutic case series, level IV.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.