Objective To evaluate early lessons from a remote patient monitoring engagement and education technology solution for patients with COVID-19 symptoms. Materials and Methods A COVID-19-specific remote patient monitoring solution (GetWell Loop) was offered to patients with COVID-19 symptoms. The program engaged patients and provided educational materials and the opportunity to share concerns. Alerts were resolved through a virtual care workforce of providers and medical students. Results Between March 18 and April 20, 2020, 2,255 of 3,701 (60.93%) patients with COVID-19 symptoms enrolled resulting in over 2,303 alerts, 4,613 messages, 13 hospital admissions, and 91 emergency room visits. A satisfaction survey was given to 300 patient respondents, 74% of whom would be extremely likely to recommend their doctor. Discussion This program provided a safe and satisfying experience for patients while minimizing COVID-19 exposure and in-person healthcare utilization. Conclusion Remote patient monitoring appears to be an effective approach for managing COVID-19 symptoms at home.
Background A substantial gap exists between current Electronic Health Record (EHR) usability and potential optimal usability. One of the fundamental reasons for this discrepancy is poor incorporation of a User-Centered Design (UCD) approach during the Graphical User Interface (GUI) development process. Objective To evaluate usability strengths and weaknesses of two widely implemented EHR GUIs for critical clinical notes usage tasks. Methods Twelve Internal Medicine resident physicians interacting with one of the two EHR systems (System-1 at Location-A and System-2 at Location-B) were observed by two usability evaluators employing an ethnographic approach. User comments and observer findings were analyzed for two critical tasks: (1) clinical notes entry and (2) related information-seeking tasks. Data were analyzed from two standpoints: (1) usability references categorized by usability evaluators as positive, negative, or equivocal and (2) usability impact of each feature measured through a 7-point severity rating scale. Findings were also validated by user responses to a post observation questionnaire. Results For clinical notes entry, System-1 surpassed System-2 with more positive (26% vs. 12%) than negative (12% vs. 34%) usability references. Greatest impact features on EHR usability (severity score pertaining to each feature) for clinical notes entry were: autopopulation (6), screen options (5.5), communication (5), copy pasting (4.5), error prevention (4.5), edit ability (4), and dictation and transcription (3.5). Both systems performed equally well on information-seeking tasks and features with greatest impacts on EHR usability were navigation for notes (7) and others (e.g., looking for ancillary data; 5.5). Ethnographic observations were supported by follow-up questionnaire responses. Conclusion This study provides usability-specific insights to inform future, improved, EHR interface that is better aligned with UCD approach.
SummaryBackground: Despite widespread electronic health record (EHR) adoption, poor EHR system usability continues to be a significant barrier to effective system use for end users. One key to addressing usability problems is to employ user testing and user-centered design. Objectives: To understand if redesigning an EHR-based navigation tool with clinician input improved user performance and satisfaction. Methods: A usability evaluation was conducted to compare two versions of a redesigned ambulatory navigator. Participants completed tasks for five patient cases using the navigators, while employing a think-aloud protocol. The tasks were based on Meaningful Use (MU) requirements. Results: The version of navigator did not affect perceived workload, and time to complete tasks was longer in the redesigned navigator. A relatively small portion of navigator content was used to complete the MU-related tasks, though navigation patterns were highly variable across participants for both navigators. Preferences for EHR navigation structures appeared to be individualized. Conclusions: This study demonstrates the importance of EHR usability assessments to evaluate group and individual performance of different interfaces and preferences for each design.
Objectives To estimate the proportion of guideline nonadherent Pap tests in women aged younger than 21 years and older than 65 years and posthysterectomy in a single large health system. Secondary objectives were to describe temporal trends and patient and health care provider characteristics associated with screening in these groups. Methods A retrospective cross-sectional chart review was performed at Fairview Health Services and University of Minnesota Physicians. Reasons for testing and patient and health care provider information were collected. Tests were designated as indicated or non-indicated per the 2012 cervical cancer screening guidelines. Point estimates and descriptive statistics were calculated. Patient and health care provider characteristics were compared between indicated and non-indicated groups using chi-squared and Wilcoxon Rank-sum tests. Results A total of 3,920 Pap tests were performed between 9/1/12–8/31/14. A total of 257 (51%; 95% CI 46.1–54.9%) of tests in the <21 years group, 536 (40%; 95% CI 37.7–43.1%) in the >65 group and 605 (29%; 95% CI 27.1–31.0%) in the posthysterectomy group were not indicated. White race in the >65 group was the only patient characteristic associated with receipt of a non-indicated Pap test (p=0.007). Provider characteristics associated with non-indicated Pap tests varied by screening group. Temporal trends showed a decrease in the proportion of non-indicated tests in the <21 years group, but an increase in the posthysterectomy group. Conclusion For women aged younger than 21 years and older than 65 years, and posthysterectomy, 35% of Pap tests performed in our health system were not guideline-adherent. There were no patient or health care provider characteristics associated with guideline nonadherent screening across all groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.