Decompression surgery for lumbar spinal stenosis is a common procedure. After surgery, segmental instability sometimes occurs, therefore, different methods for restabilization have been developed. Dynamic stabilization systems have been designed to improve segmental stability. In this study, clinical results of patients with lumbar spinal stenosis that underwent decompression and stabilization with the Accuflex dynamic system are presented; clinical, radiographic, and magnetic resonance imaging (MRI) findings are fully described. Improvements in all clinical measurements, including visual analog scale for back and leg pain, Oswestry disability index, and SF-36 health status survey were noticed. At a 2-year follow-up, 22.22% of patients required hardware removal due to fatigue while in 83% of them no progression of disk degeneration was observed after implantation of the Accuflex system. Additionally, as demonstrated by the MRI images at follow up, three patients (16%) showed disk rehydration with one grade higher on the Pfirmann classification. Although a relatively high hardware failure was observed (22.22%), the use of the dynamic stabilization system Accuflex posterior to decompression procedures, showed clinical benefits and stopped the degenerative process in 83% the patients.
The objective of the present study is to evaluate, by ultrasonography (US), the prevalence in the quadriceps, patellar, and Achilles tendon involvement of gout compared to that of patients with osteoarthritis and asymptomatic marathon runners. This is a multicenter, multinational, transverse cross-sectional, and comparative study comprising 80 patients with the diagnosis of gout according to the American College of Rheumatology (ACR) criteria, compared with two control groups: 35 patients with generalized osteoarthritis according to the ACR criteria and 35 subjects who were healthy marathon runners. Demographics and clinical characteristics, such as age, gender, comorbidity, disease duration, pain at the enthesis in the knee and ankle, frequency of disease exacerbations, uric acid level more than 7.2 mg at the time of evaluation, and type of treatment, were recorded. All participants were examined by ultrasound at the quadriceps, the patellar at its proximal and distal insertion, and the Achilles tendon to detect intra-tendinous tophus or aggregates according to the OMERACT definitions. Descriptive statistics and differences between groups were analyzed by chi-square test. Sensitivity and specificity by US were calculated. The prevalence of intra-tendinous aggregates and tophi in gout was significant compared with the other groups. Both lesions were the most frequent at the distal patellar insertion, followed by the quadriceps, Achilles, and proximal patellar insertion ones. In patients with osteoarthritis (OA), intra-tendinous hyperechoic aggregates were observed in 20 % of quadriceps tendons and in 11 % of patellar tendons at its proximal insertion, while in the healthy marathon runner group, the Achilles tendon had this kind of lesion in 17 % of the subjects. Neither the OA nor the healthy marathon runners had intra-tendinous tophi. The sensitivity and specificity of US to detect tophi or aggregates were 69.6 and 92 %, respectively, tendon involvement at the lower limbs in gout is very frequent, particularly in the patellar tendon, and US possesses good sensitivity and specificity for detecting intra-tendinous tophi.
BackgroundMusculoskeletal Ultrasonography (MSUS) is an important tool for the clinical assessment in Juvenile Idiopathic Arthritis (JIA). The objective of this study was to evaluate the reliability of MSUS to detect elementary lesions: synovitis, tenosynovitis, cartilage damage and bone erosions in the wrist and metacarpal (MCP) joints of patients with JIA.MethodsThirty children in various subgroups of JIA according to ILAR criteria, were included in this cross-sectional study. Clinical data including painful, swollen and limited joints were recorded. Five rheumatologist ultrasonographers, blinded to the clinical evaluation, evaluated the presence of elementary lesions in the wrist and MCP 2 and 3 joints bilaterally. The synovitis was graded in B-Mode and Power Doppler (PD). In addition to descriptive statistics intra- and inter-observer reliability was calculated using Cohen’s kappa according to Landis and Koch.ResultsUS detected more synovitis than the clinical examination (62% vs 28%, 30% vs 23% and 22% vs 17% in the wrist, second and third MCP joints respectively). The intra-observer concordance for synovitis in all joints was excellent in B-Mode (k 0.84 .63–1.0 p = 0.001), except for MCP 2, where it was good (0.61, IC 95% .34–89, p = 0.001). For both modalities (PD, B-Mode) tenosynovitis, cartilage damage and bone erosions it was also excellent. Regarding synovitis grading the concordance was excellent for all grades (0.83–1.0, IC 95% 0.51.1.0, p = 0.001), except for grade 1 where it was good (0.61, IC 95% 0.43–.83, p = 0.001). Reliability inter-observer for grayscale synovitis (0.67–0.95, IC 95% 0.67–1.0, p = 0.001), tenosynovitis grayscale (0.89, IC 95% 0.78–0.99, p.001), damage cartilage (0.89, IC 95% 0.78–0.99, p = 0.001), PD (0.66, IC 95% 0.39–1.0, p = 0.001). The concordance for grading synovitis was excellent, but for grayscale grade 1 and 2 (.66, IC 95% .53–.74, p = 0.007) and PD grade 1 and 2 (0.63, IC 95% .58–.91, p = 004) was good.ConclusionsThe intra- and inter-observer reliability of MSUS for inflammatory and structural lesions is good to excellent for the wrist and MCP in patients with JIA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.