To fully utilize positron emission tomography (PET) as a non-invasive tool for tissue characterization, dedicated instrumentation is being developed which is specially suited for imaging mice and rats. Semiconductor detectors, such as avalanche photodiodes (APDs), may offer an alternative to photomultiplier tubes for the readout of scintillation crystals. Since the scintillation characteristics of lutetium oxyorthosilicate (LSO) are well matched to APDs, the combination of LSO and APDs seems favourable, and the goal of this study was to build a positron tomograph with LSO-APD modules to prove the feasibility of such an approach. A prototype PET scanner based on APD readout of small, individual LSO crystals was developed for tracer studies in mice and rats. The tomograph consists of two sectors (86 mm distance), each comprising three LSO-APD modules, which can be rotated for the acquisition of complete projections. In each module, small LSO crystals (3.7 x 3.7 x 12 mm3) are individually coupled to one channel within matrices containing 2x8 square APDs (2.6 x 2.6 mm2 sensitive area per channel). The list-mode data are reconstructed with a penalized weighted least squares algorithm which includes the spatially dependent line spread function of the tomograph. Basic performance parameters were measured with phantoms and first experiments with rats and mice were conducted to introduce this methodology for biomedical imaging. The reconstructed field of view covers 68 mm, which is 80% of the total detector diameter. Image resolution was shown to be 2.4 mm within the whole reconstructed field of view. Using a lower energy threshold of 450 keV, the system sensitivity was 350 Hz/MBq for a line source in air in the centre of the field of view. In a water-filled cylinder of 4.6 cm diameter, the scatter fraction at the centre of the field of view was 16% (450 keV threshold). The count rate was linear up to 700 coincidence counts per second. In vivo studies of anaesthetized rats and mice showed the feasibility of in vivo imaging using this PET scanner. The first LSO-APD prototype tomograph has been successfully introduced for in vivo animal imaging. APD arrays in combination with LSO crystals offer new design possibilities for positron tomographs with finely granulated detector channels.
Broad spectrum: Novel para-functionalized aryl-di-tert-butylfluorosilanes, p-(tBu(2)FSi)C(6)H(4)X (X=functional group), have been made available and broaden the spectrum of silicon-based (18)F acceptors (SiFAs) for potential PET applications. For example, the [(18)F]maleimido derivative 1 has been employed for the synthesis of [(18)F]1- labeled rat serum albumin (RSA), the applicability of which for PET has been verified by in vivo experiments.The syntheses of the functionalized triorganofluorosilanes tBu(2)(p-XC(6)H(4))SiF (3 a, X=SH; 4 a, X=NCS; 4 b, X=NCO; 5, X=NC(4)H(2)O(2); 7, X=COOH; 8 a, X=COONC(4)H(4)O(2); 8 b, X=COOC(6)F(5)) are reported. These compounds display potential as silicon-based fluoride acceptors (SiFAs). The molecular structures of compounds 5, 7, and 8 a have been determined by single-crystal X-ray diffraction studies. With the exception of compounds 8 a and 8 b, all of the compounds could be (18)F-labeled by isotopic exchange in good to high radiochemical yields (RCY) with good to excellent specific activities. As proof of applicability, the maleimido-functionalized SiFA derivative 5, which is specific for thiol groups, has been used for the labeling of rat serum albumin (RSA) that had been derivatized with 2-iminothiolane. The incorporation of [(18)F]5 into the derivatized RSA reached a maximum yield after 30 min at ambient temperature. After purification, the [(18)F]RSA was evaluated in a healthy rat by means of muPET and displayed an expedient in vivo stability over 180 min.
Radiosyntheses of 18F-radiopharmaceuticals for positron emission tomography (PET) normally require an extraordinarily high effort of technical equipment and specially trained personnel. We recently reported a novel method for the introduction of fluorine-18 into peptides for PET-imaging based on silicon-18F-chemistry (SiFA technique). We herewith introduce the first SiFA-based Kit-like radio-fluorination of a protein (rat serum albumin,RSA) and demonstrate its usefulness for in vivo imaging with microPET in normal rats as well as in a rat heterotropic transplanted heart model. As a labeling agent, we prepared 4-(di-tert-butyl[18F]fluorosilyl)benzenethiol (Si[18F]FASH)by simple isotopic exchange in 40-60% radiochemical yield (RCY) and coupled it directly to a Sulfo-SMCC derivatized RSA in an overall RCY of 12% within 20-30 min. The technically simple labeling procedure does not require any elaborated purification procedures and is a straightforward example of a successful application of Si-18F chemistry for in vivo imaging with PET.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.