Diagnosing upper extremity deep vein thrombosis (UEDVT) can be challenging. Compression ultrasonography is often inconclusive because of overlying anatomic structures that hamper compressing veins. Contrast venography is invasive and has a risk of contrast allergy. Magnetic Resonance Direct Thrombus Imaging (MRDTI) and Three Dimensional Turbo Spin-echo Spectral Attenuated Inversion Recovery (3D TSE-SPAIR) are both non-contrast-enhanced Magnetic Resonance Imaging (MRI) sequences that can visualize a thrombus directly by the visualization of methemoglobin, which is formed in a fresh blood clot. MRDTI has been proven to be accurate in diagnosing deep venous thrombosis (DVT) of the leg. The primary aim of this pilot study was to test the feasibility of diagnosing UEDVT with these MRI techniques. MRDTI and 3D TSE-SPAIR were performed in 3 pilot patients who were already diagnosed with UEDVT by ultrasonography or contrast venography. In all patients, UEDVT diagnosis could be confirmed by MRDTI and 3D TSE-SPAIR in all vein segments. In conclusion, this study showed that non-contrast MRDTI and 3D TSE-SPAIR sequences may be feasible tests to diagnose UEDVT. However diagnostic accuracy and management studies have to be performed before these techniques can be routinely used in clinical practice.
Uveal melanoma (UM), the most common primary intraocular tumour, is often complicated by exudative retinal detachment (RD). Sometimes, this exudative RD is mistaken for a rhegmatogenous detachment and is subsequently treated with vitrectomy with silicone oil (SiOil) tamponade. As SiOil prevents ultrasound imaging, the diagnosis, treatment planning and/or follow-up of UM underlying the detachment are often severely hindered by the SiOil. We aim to develop and evaluate new MRI methods to image UM patients with a SiOil tamponade and evaluate this in vivo. A dedicated MRI protocol for 3 and 7 T was developed and subsequently evaluated in three patients. The MRI protocol developed was evaluated in three patients. In the first patient, SiOil hindered follow-up and therefore MRI was indicated. No tumour recurrence was found after two follow-up scans. The second and third patient underwent vitrectomy with SiOil for assumed rhegmatogenous RD in another hospital, during which a mass was found. In these cases, MRI was used to determine whether the lesion was UM and perform measurements to plan brachytherapy treatment. In general, the proposed workflow is more complicated on 7 T than on 3 T as the off-resonance effects scale linearly with field strength. For example, the shimming procedure needed modifications at 7 T, whereas at 3 T, the automatic shimming sufficed. However, at 7 T, higher resolution images were obtained compared with 3 T (0.6 vs. 0.8 mm3). A dedicated MRI protocol enables high-resolution imaging of vitrectomized eyes with SiOil tamponade, enabling treatment planning or follow-up in UM patients.
This is an open access article under the terms of the Creat ive Commo ns Attri butio n-NonCo mmerc ial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
Introduction Magnetic resonance direct thrombus imaging (MRDTI) is a promising technique to improve the diagnostic management of patients with a suspected ipsilateral recurrent deep vein thrombosis (DVT) by direct visualization of a thrombus. Another magnetic resonance imaging (MRI) technique, T1-weighted turbo spin-echo spectral attenuated inversion recovery (TSE-SPAIR), has the potential to image a thrombus directly with a high spatial resolution as well. The main aim of this pilot study was to investigate if adding the TSE-SPAIR sequence to an MRDTI sequence performed in patients with suspected recurrent DVT may increase the diagnostic confidence of expert MRDTI readers.
Methods Fifteen patients with suspected acute recurrent DVT were included in this study. The TSE-SPAIR sequence was scanned directly after the MRDTI scan but not used to guide clinical decision making, and both scans were adjudicated post hoc two times separately by three independent expert MRDTI readers. Diagnostic confidence was scored on a 4-point Likert scale: (1) poor (definite diagnosis impossible), (2) fair (evaluation of major findings possible), (3) good (definite diagnosis possible), and (4) excellent (exact diagnosis possible).
Results The diagnostic confidence of expert readers increased when adding the TSE-SPAIR sequence on top of the MRDTI sequence from “good” (median, 3.0; interquartile range [IQR], 2.66–3.0) to “excellent” (median, 3.67; IQR 3.33–3.67; p = 0.001). Evaluation of the scans in the reversed order 5 months after initial reading showed similar results. Diagnostic accuracy for proximal DVT of both scan techniques was good.
Conclusion The extra TSE-SPAIR sequence may help increase diagnostic confidence of radiologists in cases of uncertain diagnosis in patients with suspected ipsilateral recurrent DVT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.