As it provides results of exophthalmometry for the Turkish population, our study is important. However, larger, nationwide, and multisite studies examining more subjects may provide more valuable data about the Turkish population.
Objectives:To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before.Materials and Methods:Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 °C in 15% glycerol in the microbiology laboratory of the Anadolu University Department of Biology were purified and used in the study. The isolates were S. epidermidis KA 15.8 (ICA+), a known biofilm producer isolate positive for icaA, icaD and bap genes, and S. epidermidis KA 14.5 (ICA-), known as a non-biofilm producer isolate negative for icaA, icaD and bap genes. The biofilm formation capacities of the 2 isolates on 4 different IOLs were compared. Two of the IOLs were acrylic (UD613 [IOL A], Turkey; SA60AT [IOL B], USA), and the other two were polymethyl methacrylate (PMMA) (B60130C [IOL C], India; B55125C [IOL D], India). Bacterial enumeration and optical density measurements were done from biofilms that formed on the IOLs. Biofilms were imaged using scanning electron microscopy.Results:Mean bacterial counts on the IOLs were 7.1±0.4 log10 CFU/mL with the ICA+ isolate, and 6.7±0.8 log10 CFU/mL with the ICA- isolate; there were no statistically significant differences. Biofilm formation was lower with acrylic lenses than PMMA lenses with both isolates (p=0.009 and p=0.013). The highest biofilm production was obtained on IOL C (PMMA) (p<0.001) and the lowest was obtained on IOL A (hydrophilic acrylic) (p<0.001).Conclusion:Bacterial counts after biofilm formation were lower on acrylic lenses, especially hydrophilic acrylic with hydrophobic properties. Further animal and in vivo studies are required to support the findings of this study.
To describe a congenital retinal macrovessel with macular thickening. This case was investigated using fundus photography, fluorescein angiography, Spectralis optical coherence tomography and a 10-2 visual field test. A 23-year-old man was referred to our clinic with decreased vision in the right eye. Fundus examination of the right eye revealed a congenital retinal macrovessel that originated inferior to the superotemporal branch of the central retinal vein. Using fluorescein angiography, early filling and delayed emptying of the aberrant vein were observed. Spectralis optical coherence tomography demonstrated macular thickening and was supported by a 10-2 visual field test that revealed a relative scotoma corresponding to the same location. At the 18-month follow-up, visual acuity remained stable. Although rare, this case demonstrated that macular thickening can cause decreased visual acuity in the presence of a congenital retinal macrovessel.
Trachoma continues to be a serious public health threat in Erzurum, and eyelid examination is the most suitable method of diagnosis for surveillance of trachoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.