A novel preparative size-exclusion electrochromatography with an oscillatory low-voltage electric field perpendicular to the liquid phase streamline (pSEEC) was proposed with a column design of rectangular cross-section. The column of 12 cm length was packed with Sephadex G-75, and the retention behavior of bovine serum albumin (BSA) and myoglobin (Myo) was extensively investigated under various conditions. The results indicated that the partition coefficient of a charged protein increased significantly on increasing the current strength as well as the difference between its pI and pH. The partition coefficient also increased on decreasing the mobile phase conductivity. For the gel-excluded protein like BSA, the concentration polarization (CP) on the gel surface induced by the protein electromigration was the main reason for the increased retention. For a gel-permeable protein like Myo, both the CP and electrophoretic migration in the solid phase contributed to its increased retention. Further results exhibited that the polarization would be offset by diffusion, because the accumulated protein would flux back to the bulk liquid phase. Therefore, when the electrically induced mass flux was equal to the diffusion flux, the partition coefficient did not change with a further increase of the oscillatory current cycle. Finally, pSEEC was compared with SEC in the separation of protein mixtures of BSA/Myo as well as BSA/Myo/lysozyme. The results showed much better resolutions of the protein mixtures in pSEEC with the column as short as 12 cm. The potential of pSEEC for preparative protein separation was therefore demonstrated.
Protein separations by a novel size-exclusion electrochromatography (SEEC) are presented. The present SEEC, denoted as pSEEC, was established with an oscillatory low-voltage electric field perpendicular to the mobile-phase streamline. Retention experiments with different proteins indicated that the influence of electric field strength on the partition coefficient is different for different proteins as well as for the same protein under different mobile-phase conditions. These results of protein retention led to the experimental design of protein separations with binary mixtures of BSA and immunoglobulin G (IgG), myoglobin (Myo) and lysozyme (Lys), as well as ovalbumin (Oval) and Myo. The separation results for the binary protein systems sufficiently exhibited the applicability of the pSEEC for various separations in terms of their molecular weights (MWs) as well as pIs. For example, it was possible to separate the gel-excluded proteins (BSA/IgG) as well as gel-permeable and similar-molecular-weight proteins (Myo/Lys) by the pSEEC. Moreover, in the cases of Oval/ Myo, which could be partially separated by size-exclusion chromatography, the use of the pSEEC greatly improved the resolution and the separation became possible at high sample loading. The results indicate that the pSEEC technology is promising for preparative protein separations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.