Dielectric properties (DPs), as a physical property, are widely used in real-time identification of normal or tumor tissue in vivo. Open-ended coaxial probe method is one of the most common modalities in measuring DPs. This technique secures its promising potential in early-stage skin cancer diagnosis for its non-invasive merit. Although various studies have been reported, systematic assessment is lacking to advance to clinical applications. Parameter interactions and detecting limitations remain unclear. In this study, we examine the minimum detectable size of tumor by using a three-layer skin model by simulation. DP changes under different tumor dimension, probe size, skin thickness, and cancer type were discussed. The smallest detecting size of BCC inside the skin is 0.5 mm radius × 0.1 mm; for SCC inside the skin is 1.4 mm × 1.3 mm in radius and height; the smallest distinguishing size of BCC is 0.6 mm × 0.7 mm in radius and height; for SCC is 1.0 mm × 1.0 mm in radius and height; for MM is 0.7 mm × 0.4 mm in radius and height. We also provide a detailed systematic evaluation of the parameters employed in the method for further applications.
Dielectric properties (DPs), as a physical property, are widely used in real-time identification of normal or tumor tissue in vivo. Open-ended coaxial probe method is one of the most common modalities in measuring DPs. This technique secures its promising potential in early-stage skin cancer diagnosis for its non-invasive merit. Although various studies have been reported, systematic assessment is lacking to advance to clinical applications. Parameter interactions and detecting limitations remain unclear. In this study, we examine the minimum detectable size of tumor by using a three-layer skin model by simulation. DP changes under different tumor dimension, probe size, skin thickness, and cancer type were discussed. The smallest detecting size of BCC inside the skin is 0.5 mm radius × 0.1 mm; for SCC inside the skin is 1.4 mm × 1.3 mm in radius and height; the smallest distinguishing size of BCC is 0.6 mm × 0.7 mm in radius and height; for SCC is 1.0 mm × 1.0 mm in radius and height; for MM is 0.7 mm × 0.4 mm in radius and height. We also provide a detailed systematic evaluation of the parameters employed in the method for further applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.