In response to the difficulty of weak detection of early bearing damage, resonance demodulation technology and the principle of fiber Bragg grating sensing strain were combined to design a fiber Bragg grating generalized resonance sensor, which can extract the weak pulse signal of weak detection of early bearing’s early damage from rolling bearing. First, a principle of resonance dynamics of second-order mechanical systems based on fiber Bragg grating and generalized resonance principles is proposed. Second, the basic structure of the sensor is designed. Then, ANSYS finite element simulation is used to analyze the natural frequency of the sensor. Finally, the natural frequency value of the sensor was obtained through experiments. The experimental results of proof-of-principle show that the experimental results are consistent with the theoretical predictions. The theoretical model is accurate, which verifies the feasibility of the sensor.
This paper aims at solving the problem of explosion proof in measurement of thermal gas flow using electronic sensor by presenting a new type of flow sensor by optical fiber heating. A measuring unit based on fiber Bragg grating (FBG) for fluid temperature and a unit for heat dissipation are designed to replace the traditional electronic sensors. The light in C band from the amplified spontaneous emission (ASE) light source is split, with one part used to heat the absorbing coating and the other part used in the signal processing unit. In the heating unit, an absorbing coating is introduced to replace the traditional resistance heating module to minimize the risk of explosion. The measurement results demonstrate a fine consistency between the flow and temperature difference in simulation. The method to enhance the measurement resolution of flow is also discussed.
Abstract:In this paper, a differential pressure sensor with magnetic transfer is proposed, in which the non-electric measurement based on the fiber Bragg grating (FBG) with the position limiting mechanism is implemented without the direct contact of the sensing unit with the measuring fluid. The test shows that the designed sensor is effective for measuring differential pressure in the range of 0~10 kPa with a sensitivity of 0.0112 nm/kPa, which can be used in environments with high temperature, strong corrosion and high overload measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.