Carbamazepine is a drug with a narrow therapeutic range that requires clinical monitoring, since its toxic effects are not easily predictable, and the therapeutic level can vary. Our study aimed to monitor the serum level and determine the concentration/dose relationship of carbamazepine in people with epilepsy, analyzing its clinical implication. It is observed that 90.48% of the study volunteers present serum level values (4.3–10.4 mg/L) within the therapeutic range (4–12 mg/L); 7.14% present supratherapeutic levels (12.7–14.4 mg/L), 2.38% subtherapeutic (0.93 mg/L). The findings indicate a negative correlation (r = -0.616; r2 = 0.379; p = 0.001), between the dose (mg/day) and the dose ratio (mg/L/mg/day); and a positive correlation (r = 0.544; r2 = 0.296; p = 0.002), between the dose (mg/day)-serum concentration (mg/L). ANOVA and Tukey’s test mean difference is significant (p<0.05). It is concluded that there is a positive and significant linear correlation between daily doses and serum carbamazepine concentrations, which should be considered to individualize the dose and optimize clinical results.
In clinical practice, therapeutic drug monitoring (TDM) makes it possible to measure the concentration of drugs in serum or saliva, the purpose of which is to reduce adverse effects and optimize pharmacological therapy. The objective was to determine the concentrations of Phenytoin in saliva and serum of people with epilepsy. Cross-sectional, descriptive study with dynamic recruitment of 30 people with epilepsy (n = 30; 17 men, 56.7% and 13 women, 43.3%; mean age 33.9 ± 11.83 years). Serum and saliva samples were collected at trough levels from patients, who were under phenytoin treatment for at least three months. Drug levels were assessed by the Cloned Donor Enzyme Immunoassay method. Phenytoin levels were found in saliva between 0.01 to 3.56 mg/L and in serum between 0.09 to 36.60 mg/L. Pearson’s analysis showed an association between the estimated serum and saliva phenytoin concentrations (R2 0.7026; 95% CI 0.685-0.921), with a significant statistical correlation (p < 0.05). The Bland-Altman test broke concordance, the difference between the two saliva/serum methods is within 95% confidence. It is concluded that there is an association and concordance between the concentrations of phenytoin in serum and saliva, therefore, this technique can be useful in the clinical monitoring of phenytoin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.