Purpose The behavior of high-performance concrete (HPC) at high temperatures is very complex and also affects the global behavior of heated HPC-based structures. Researchers have also reported how various types of fibers affected the mechanical properties of cement-based materials at high temperatures. This study aims to discuss the effects of high temperatures on the compressive strength and elastic modulus of HPC with polypropylene (PP) and jute fiber. Design/methodology/approach Adding synthetic fiber (especially the PP type) to HPC is a widely used and effective method of preventing explosive spalling. Although researchers have experimentally determined the permeability of heated PP-fiber-reinforced HPC, few studies have investigated how adding natural fiber such as jute to this type of concrete might prevent spalling. In this study, the effects of high temperatures on the compressive strength and elastic modulus of HPC with PP and jute fiber (jute fiber addition ratio: 0.075 vol.%; length: 12 mm; PP fiber addition ratio: 0.075 vol.%; length: 12 mm) were experimentally investigated. Findings The work was intended to clarify the influence of elevated temperatures ranging from 20°C to 500°C on the material mechanical properties of HPC at 80 MPa. HSC with jute fiber showed a compressive strength loss of about 40 per cent at 100°C before recovering to full strength between 200°C and 300°C. Originality/value The elastic modulus of high-strength concrete decreased by 10-40 per cent between 100°C and 300°C. At 500°C, the elastic modulus was only 30 per cent of the room temperature value. The thermal expansion strain of all specimens was 0.006 at 500°C.
In construction field, it used various technique for concrete formwork. Part of them, non-destructive test has been conducted to estimate a compressive strength of concrete easily such as rebound method and ultrasonic pulse velocity method etc. Former research has recommend proposed equation based on experimental data to investigate strength of concrete but it was sometimes deferent actual value of that from in field because of the few of data in case of early strength concrete. In this study, an experiment was conducted to analyze strength properties for early strength concrete using cylinder mold and 1,000mm×1,000mm×200mm rectangular specimen. And compressive strength of concrete was tested by non-destructive test, and calculated by the equation proposed former research. As a result, the non-destructive test results showed approximately 70 percent of the failure test value for all conditions, and worse reliability was obtained for high strength concrete samples when the ultrasonic pulse velocity method was used. Based on the scope of this study, the experimental equation for estimating compressive strength of early strength concrete from 24MPa to 60MPa was proposed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.