We present a 640 × 480 CMOS image sensor (CIS) with in-circuit bi-directional gamma correction with a proposed digital-correlated double sampling (CDS) structure. To operate the gamma correction in the CIS, the transfer function of the analog-to-digital converter can be changed by controlling the clock frequency of the counter using analog CDS. However, the analog CDS is vulnerable to capacitor mismatch, clock feedthrough, etc. Therefore, we propose a digital-CDS method with a hold-and-go counter structure to operate the bi-directional gamma correction in the CIS. The proposed CIS achieves a 10-bit resolution using a global log-exponential counter and configurable column reset counter with a resolution of 8/9 bits. The sensor was fabricated in a 0.11 μm CIS process, and the full chip area was 5.9 mm × 5.24 mm. The measurement results showed a maximum SNR improvement of 10.41% with the proposed bi-directional gamma-corrected digital-CDS with the hold-and-go counter. The total power consumption was 6.3 mW at a rate of 16.6 frames per second with analog, pixel, and digital supply voltages of 3.3 V, 3.3 V, and 1.5 V, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.