Digital Breast Tomosynthesis (DBT) is performing in high resolution limited angle tomography at radiographic dose levels. Advanced system facilitates the DBT along with 2 view Full Field Digital mammography (FFDM). The objectives of this study were to compare the Average Glandular Dose (AGD) ofDBT and FFDM and tocalculate the percentage of radiation dose reduction when using DBT with compare toFFDM. The study was carried out using data base of DBTsystem in a private hospital. In the investigation we analyzed dose of 251 patients who underwent mammographic examinations of both FFDM and DBT. All data analyses were done using IBM SPSS statistical software version 20.0.P-value 0.05 was considered as statistically significant. The explanatory variables were age, breast thickness, kVp, mAs, target/filter combination, and AGD values of DBT and FFDM. Mean values for the patient age and compressed breast thickness were 50 years and 49 mm(±11.9SD) respectively. The majority of the images were acquired using W/Rh target/filter combination and 51% patients came for the diagnostic mammograms and 49% for screening mammograms. A wide kVp range was observed for DBT than FFDM while mAs range was lower in DBT.According to the results total average glandular dose (TAGD) from FFDM and DBT for diagnostic was 4.21mGy (±1.46SD), for screening 4.04(±1.31SD) andthere was a statistically significant difference between mean values of TAGD. MeanAGD forMediolataral Oblique (MLO) view in DBT was 2.05mGy(±0.60SD), in FFDM 2.73mGy(±1.02SD).AGD for Craniocadal (CC) view in DBT was 1.63mGy(±0.36SD) and for FFDM it was 1.83mGy(±0.66SD).AGDto the breast from DBT was significantly lower than that for FFDM while range was lower in FFDM than DBT. There was a significant difference between mean values of CC and MLO views in DBT and FFDM (P<0.05). It was evident that AGD from DBT was lower than that for FFDMfurther AGD was reduced by 55.3% by using DBT with compared to TAGD,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.