Hydraulic pump failures may be related to hardware or problem in oil. In this study, the excavator hydraulic pump failures were investigated by using visual observed and measuring the part component. The disassembled process of the pump was performed considering the manual part book of the excavator hydraulic pump. The abrasive wear on the pump slipper and swash plate was observed by comparing the guidelines for the reusable part. The value of more than 1.07 mm clearance within piston and cylinder bore was measured then the results over the allowable limit considering the manual part book. Properly analyzing of component failure can provide valuable information about what caused the failure and thus can be to avoiding future unscheduled downtime.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.