Objective: Our objective was to report our experience and to evaluate the feasibility and toxicity of focal salvage stereotactic body radiation therapy (SBRT) in patients with post-radiation local recurrence of prostate cancer. Methods: We retrospectively reviewed medical records of patients treated with Cyberknife ® between October 2014 and April 2017 at our institution for a focal reirradiation delivered to the prostate/prostatic bed for local recurrence after radical or adjuvant radiotherapy. All patients underwent prostate biopsies at recurrence at the time of fiducial markers placement, had choline PET/CT and pelvic MRI. The treatment consisted in 36 Gy in six fractions delivered every other day. Post reirradiation toxicities were assessed according to the CTCAE v4 (Common Terminology Criteria for Adverse Events). Results: 42 patients were treated with followed with a median follow-up of 21 months (range 3 – 31). 34 patients had biopsy proven recurrence. The initial treatment was radical prostatectomy and radiation therapy for 9 patients and radiation therapy alone for 33 patients. 23 patients from the group of prostate reirradiation had placement of rectal spacers. No Grade 4 or 5 toxicity were observed. 27 acute urinary events were recorded: 18 patients experienced Grade 1, 9 patients experienced Grade 2 toxicity and 1 patient experienced Grade 3 urinary toxicity, namely cystitis and/or dysuria. No Grade 2 or more digestive toxicity was observed. Rectal doses were significantly lower with rectal spacers. Conclusion: Salvage focal Cyberknife ® seems feasible and show promising results. Advances in knowledge: SBRT for local prostate cancer recurrence after initial radiotherapy is well tolerated with short follow-up.
Purpose The purpose of this study was to assess the feasibility, efficacy and toxicity of fiducial marker implantation and tracking in CyberKnife® stereotactic radiation therapy (SBRT) applied to extracranial locations. Materials and method This is a retrospective, single-centre, observational study to collect the data of all patients treated by stereotactic radiation therapy with fiducial marker tracking at extracranial locations, conducted between June 2014 and November 2017. Information regarding the implantation procedure, the types of toxicity related to marker implantation and the number of markers implanted/tracked during treatment were collected. Complication rates were evaluated using the CTCAE v4 [Common Terminology Criteria for Adverse Events] scale. The technical success rate was based on the ability to optimally track the tumor throughout all treatment fractions. Results Out of 2505 patients treated by stereotactic radiation therapy, 25% received treatment with fiducial marker tracking. The total number of implantation procedures was 616 and 1543 fiducial markers were implanted. The implantation-related complication rate was 3%, with 16 Grade 1 events and 4 Grade 2 events. The number of treated patients and the number of implanted markers has gradually increased since the technique was first implemented. The median treatment time was 27 min (range 10–76). 1295 fiducials were effectively tracked throughout all treatment fractions, corresponding to a technical success rate of 84%. The difference between the number of fiducials implanted and those tracked during treatment decreased significantly as the site’s experience increased. Conclusion Fiducial marker implantation and tracking is feasible, well-tolerated, and technically effective technique in SBRT for extracranial tumors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.