Background and Aim of the Study The frozen elephant trunk (FET) procedure became a popular entity for utilization in aortic arch aneurysm disease. However, its proper mortality and morbidities as well as the predictors of outcomes are poorly identified. This systematic review and meta‐analysis explore FET outcomes and its predictors with a focus on zone aortic proximalization. Methods We searched PubMed/MEDLINE, EMBASE, and Scopus databases from their beginning to June 2020 to find studies reporting the outcomes of the FET procedure for the total arch replacement (TAR). Results A total of 64 studies including 7967 patients were evaluated. The pooled estimates of cerebrovascular accidents, paraplegia, renal failure, and in‐hospital mortality were 7.104 (95% confidence interval [CI], 5.691–8.661; I2 = 78.53%), 3.465 (95% CI, 2.852–4.136; I2 = 15.96), 14.969 (95% CI, 11.361–18.977; I2 = 91.26%), and 8.933 (95% CI, 7.128–10.919; I2 = 78.51%), respectively. Stratification by the geographical locations and by the aortic pathologies led to lower heterogeneity, but not for renal failure. The distal anastomosis in Zone 2 was associated with a lower rate of renal failure compared with Zone 3 (odds ratio, 0.54; 95% CI, 0.36–0.81; p = .003; I2 = 0%). Conclusions The FET procedure for TAR can be performed with acceptable mortality and morbidities among patients with complex aortic pathologies. Moreover, the distal anastomosis in Zone 2 was associated with lower renal failure compared to Zone 3.
Background The treatment of complex thoracic aorta pathologies remains a challenge for cardiovascular surgeons. After introducing Frozen Elephant Trunk (FET), a significant evolution of surgical techniques has been achieved. The present meta‐analysis aimed to assess the efficacy of FET in acute type A aortic dissection (ATAAD) and the effect of circulatory arrest time on post‐operative neurologic outcomes. Methods A standard Preferred Reporting Items for Systematic Reviews and Meta‐Analyses search was conducted for all observational studies of patients diagnosed with ATAAD undergoing total arch replacement with FET reporting in‐hospital mortality, bleeding, and neurological outcomes. A random‐effect meta‐analysis was performed using STATA software (StataCorp, TX, USA). Results Thirty‐five studies were eligible for the present meta‐analysis, including 3211 patients with ATAAD who underwent total arch replacement with FET. The pooled estimate for in‐hospital mortality, postoperative stroke, and spinal cord injury were 7% (95% CI 5 – 9; I2 = 68.65%), 5% (95% CI 4 – 7; I2 = 63.93%), and 3% (95% CI 2 – 4; I2 = 19.56%), respectively. Univariate meta‐regression revealed that with increasing the duration of hypothermic circulatory arrest time, the effect sizes for postoperative stroke and SCI enhances. Conclusions It seems that employing the FET procedure for acute type A dissection is associated with acceptable neurologic outcomes and a similar mortality rate comparing with other aorta pathologies. Besides, increasing hypothermic circulation arrest time appears to be a significant predictor of adverse neurologic outcomes after FET.
Background: The treatment of complex thoracic aorta pathologies remains a challenge for cardiovascular surgeons. After introducing Frozen Elephant Trunk (FET), a significant evolution of surgical techniques has been achieved. The present meta-analysis aimed to assess the efficacy of FET in acute type A aortic dissection (ATAAD) and the effect of circulatory arrest time on post-operative neurologic outcomes. Methods: A standard Preferred Reporting Items for Systematic Reviews and Meta-Analyses search was conducted for all observational studies of patients diagnosed with ATAAD undergoing total arch replacement with FET reporting in-hospital mortality, bleeding, and neurological outcomes. A random-effect meta-analysis was performed using STATA software (StataCorp, TX, USA). Results: Thirty-five studies were eligible for the present meta-analysis, including 3211 patients with ATAAD who underwent total arch replacement with FET. The pooled estimate for in-hospital mortality, postoperative stroke, and spinal cord injury were 7% (95% CI 5 – 9; I2 = 68.65%), 5% (95% CI 4 – 7; I2 = 63.93%), and 3% (95% CI 2 – 4; I2 = 19.56%), respectively. Univariate meta-regression revealed that with increasing the duration of hypothermic circulatory arrest time, the effect sizes for postoperative stroke and SCI enhances. Conclusions: It seems that employing the FET procedure for acute type A dissection is associated with acceptable neurologic outcomes and a similar mortality rate comparing with other aorta pathologies. Besides, increasing hypothermic circulation arrest time appears to be a significant predictor of adverse neurologic outcomes after FET.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.