Study design Two-center retrospective cohort study. Objective The aim of this study is to investigate the clinical effectiveness and safety of the MCGR hybrid in terms of spinal growth, 3D correction, balance, and complications. Summary of background data The magnetic-controlled growing-rod (MCGR) growth instrumentation method has gained popularity for early onset scoliosis (EOS) treatment in the past years due to the non-invasiveness of the subsequent interval elongation procedures. To improve 3D correction and reduce the costs, we combined a single concave MCGR with a sliding rod on the convex side to control the apex. Methods A retrospective cohort study of 18 EOS children with an average 3-year follow-up (range 2.0-3.7) from two European spine centers treated with the single MCGR hybrid concept; 14 primary and 4 conversion cases. The primary and conversion cases were both evaluated preoperatively, postoperatively, 1 year, 2 years, and last follow-up. Results Mean age was 9.9 (SD ± 2.9 years). The average frontal Cobb angle was reduced from mean 65° to 30° postoperatively, and had increased to 37° at latest follow-up. Rotation of the apical vertebra improved from mean 27° to 20° postoperatively which was partially lost to 23°. Kyphosis and lordosis both increased by an average of 5° during the time of follow-up. Spinal balance was improved. The post-implantation T1-S1 spine growth rate averaged 10 mm/year at last follow-up. There were 13 implant-related complications in 6 out of 18 patients. No screw pull-outs and nor surgical site infections were registered. Conclusions This is the first medium-term results of a single MCGR hybrid construct. Maintenance of correction and growth are reasonable, and the complication rate is relatively low as compared to bilateral MCGR application. Level of evidence III.
To explore the effectiveness of posterior vertebral column resection for failed thoracolumbar anterior instrumented fusion.
Ten patients with anterior fusion with refractory pain, progressive neurological deficits, and kyphosis were recruited. Anterior removal of the implant and posterior vertebral column resection were performed. The mean operating time, intraoperative blood loss, kyphosis angle, visual analog scale pain score, Oswestry disability index, bone fusion time, and complications were assessed in a minimum 18-month follow-up.
The mean operating time was 323.5 ± 63.6 minutes, with a mean blood loss of 1189 ± 253.4 mL. The mean preoperative kyphosis angle of 54.6° ± 8.0° immediately decreased to 4.8° ± 1.5° after revision surgery and eventually to 6.8° ± 1.3° at the final follow-up. The mean bone fusion time was 6.8 ± 1.2 months. All patients had satisfactory sagittal and coronal balance with no implant failure at the last follow-up. The average visual analog scale score was 6.2 ± 1.0 preoperatively, and it decreased to 2.6 ± 0.5 at the last follow-up. No patient suffered from neurological deterioration. The Oswestry disability index decreased from 39.8% ± 4.6% preoperatively to 24.5% ± 4.7% at the final follow-up. Complications occurred in 4 patients: 3 experienced tearing of the lung, and 1 had a superficial wound infection.
Anterior removal of the implant and posterior vertebral column resection constituted a safe and effective revision surgery for patients with prior anterior fusion with rigid postsurgical deformities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.