In many sports, the hamstring strain injury is a common injury. There is evidence that the Nordic hamstring exercise (NHE), a knee flexor exercise, can reduce hamstring injury risk in athletes. In research on hamstring injury prevention, eccentric-only NHE is typically performed, whereas in sports, it is relatively common for athletes to perform NHE eccentrically-concentrically. Further, NHE strength is generally assessed by measuring knee flexor force through an ankle brace, attached atop of a load cell. An alternative method might be to assess knee flexor force about the knee joint using a force plate. The aim of the study was to investigate differences in peak knee flexor force between eccentric-only and combined eccentric-concentric NHE. The purpose was also to determine the correlation between hamstring force measured at the ankle using a load cell (current gold standard) and force assessed about the knee joint using a force plate during NHE. Fifteen junior and senior elite soccer and track and field athletes (3 women and 12 men aged 17–27 years) performed eccentric NHE (ENHE) in which they leaned forward as far as possible until breakpoint and eccentric-concentric NHE (ECNHE) where they returned to the starting position. A linear encoder measured the position at which peak force occurred during the NHEs. Force assessed at the ankle differed significantly (678 vs. 600 N, p < 0.05), whereas force about the knee joint did not (640 vs. 607 N, p > 0.05) between ENHE and ECNHE (12 and 5% difference, respectively). The forward distance achieved by the participants in cm at breakpoint for ENHE was 37% higher than at the coupling phase for ECNHE (74 vs. 54 cm, p < 0.001). Very strong significant (p < 0.01) correlations were noted between peak force assessed at the ankle and about the knee joint for ENHE and ECNHE, r = 0.96 and r = 0.99, respectively. Our results suggest that ECNHE, where peak knee flexor force was reached with 37% less forward movement, may complement ENHE, i.e., during hamstring injury rehabilitation, where a position of great knee extension may not be well tolerated by the athlete. Further, assessing knee flexor force about the knee joint using a force plate may provide an alternative to measuring force at the ankle using a load cell when testing NHE strength.
Hamstring strain injuries are prevalent in many sports. Research has demonstrated that the Nordic hamstring exercise (NHE), a knee-dominant exercise addressing the posterior chain muscles, can aid in reducing the risk of hamstring injuries in athletes. However, most research on hamstring injury prevention has focused on performing the eccentric version of the NHE (NHEECC). In contrast, in sports, it is quite frequent for athletes to use an eccentric–concentric version of the NHE. Additionally, eccentric NHE is typically performed using a slow, controlled tempo. The effect of a fast stretch-shortening cycle NHE (NHESSC) compared to standard slow NHEECC on peak knee flexor force has not been investigated. The aim of the study was therefore to investigate fast NHESSC vs. standard slow NHEECC. Our hypothesis posited that peak knee flexor force would be greater for fast NHESSC compared with standard slow NHEECC. The study involved 22 elite athletes (actively competing in both national and international events) consisting of female (n = 10) and male (n = 7) track and field athletes and male football players (n = 5), aged 17–31 years. The participants performed maximum trials of slow NHEECC and fast NHESSC repetitions in which measurement of bilateral peak knee flexor force was conducted at the ankle with the use of a load cell. During the NHEs, a linear encoder was used to measure both the position where the peak knee flexor force was recorded and the average eccentric velocity. SSC contributed to an enhanced NHE performance, where bilateral absolute peak knee flexor force was 13% higher for fast NHESSC vs. standard slow NHEECC (822 vs. 726 N, p < 0.01, ES = 0.54). Participants achieved a 32% greater forward distance at the breakpoint stage during NHEECC compared to the coupling phase for NHESSC (54 vs. 41 cm, p < 0.001, ES = 1.37). Eccentric average velocity was more than three times higher for NHESSC compared with NHEECC (0.38 vs. 0.12 m/s, p < 0.001, ES = 3.25). The key findings of this study were that SSC contributed to an enhanced NHE performance, where absolute peak knee flexor force was 13% greater for fast NHESSC compared to standard slow NHEECC. The fast NHESSC could therefore be an interesting alternative to the standard slow NHEECC execution, as it may offer potential advantages for sprint performance, as well as hamstring injury prevention and rehabilitation.
Supplemental Digital Content is Available in the Text.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.