An isocratic reversed-phase high-performance liquid chromatography method with UV detection is developed and validated for the simultaneous determination of ketamine, xylazine, and midazolam in canine plasma. Analytes are extracted from alkalinized samples into diethyl ether-methylene chloride (7:3, v:v) using single-step liquid-liquid extraction. Chromatographic separation is performed on a C(18) column using a mobile phase containing an acetonitrile-methanol-10 mM sodium heptanesulfonate buffer adjusted to pH 3, with glacial acetic acid (44:10:46, v:v) at a detection wavelength of 210 nm, with a total runtime of 10 min. The calibration is linear over the range of 78.125-5000 ng/mL for ketamine and 15.625-1000 ng/mL for xylazine and midazolam. The limits of detection are 17.8, 10.3, and 15.1 ng/mL for ketamine, xylazine, and midazolam, respectively. The extraction recoveries are 76.1% for ketamine, 91.0% for midazolam, and 78.2% for xylazine. The method is successfully used for clinical and pharmacokinetic studies of the three-drug fixed dose combination formulations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.