Purpose
The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading.
Methods
Twelve patients were recruited. Two types of implants were placed adjacent to each other: 1 straight implant and 1 tapered implant. Marginal bone loss, mPI, and mBI were measured every year for 5 years after loading.
Results
The straight implants showed 0.2±0.4 mm of marginal bone loss at 5 years after loading, while the tapered implants showed 0.2±0.3 mm of marginal bone loss; this difference was not statistically significant (
P=
0.833). Our analysis also showed no statistically significant differences in mPI (straight implants: 0.3±0.3 vs. tapered implants: 0.2±0.3;
P=
0.414) or in mBI (straight implants: 0.3±0.4 vs. tapered implants: 0.2±0.3;
P=
0.317) at 5 years after prosthesis delivery.
Conclusions
Straight and tapered implants showed no significant differences with respect to marginal bone loss, mPI, and mBI for 5 years after loading.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.