Acoustic emission (AE) technology is a non-destructive testing (NDT) technique that is able to monitor the process of hydrogen-induced cracking (HIC). AE uses piezoelectric sensors to convert the elastic waves generated from the growth of HIC into electric signals. Most piezoelectric sensors have resonance and thus are effective for a certain frequency range, and they will fundamentally affect the monitoring results. In this study, two commonly used AE sensors (Nano30 and VS150-RIC) were used for monitoring HIC processes using the electrochemical hydrogen-charging method under laboratory conditions. Obtained signals were analyzed and compared on three aspects, i.e., in signal acquisition, signal discrimination, and source location to demonstrate the influences of the two types of AE sensors. A basic reference for the selection of sensors for HIC monitoring is provided according to different test purposes and monitoring environments. Results show that signal characteristics from different mechanisms can be identified more clearly by Nano30, which is conducive to signal classification. VS150-RIC can identify HIC signals better and provide source locations more accurately. It can also acquire low-energy signals better, which is more suitable for monitoring over a long distance.
One of the most significant benefits of Acoustic Emission (AE) testing over other Non-Destructive Evaluation (NDE) techniques lies in its damage location capability over a wide area. The delta-T mapping technique developed by researchers has been shown to enable AE source location to a high level of accuracy in complex structures. However, the time-consuming and laborious data training process of the delta-T mapping technique has prevented this technique from large-scale application on large complex structures. In order to solve this problem, a Finite Element (FE) method was applied to model training data for localization of experimental AE events on a complex plate. Firstly, the FE model was validated through demonstrating consistency between simulated data and the experimental data in the study of Hsu-Nielsen (H-N) sources on a simple plate. Then, the FE model with the same parameters was applied to a planar location problem on a complex plate. It has been demonstrated that FE generated delta-T mapping data can achieve a reasonable degree of source location accuracy with an average error of 3.88 mm whilst decreasing the time and effort required for manually collecting and processing the training data.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.