Recently published studies not only demonstrated that laser printers are often significant sources of ultrafine particles, but they also shed light on particle formation mechanisms.While the role of fuser roller temperature as a factor affecting particle formation rate has been postulated, its impact has never been quantified. To address this gap in knowledge, this study measured emissions from 30 laser printers in chamber using a standardized printing sequence, as well as monitoring fuser roller temperature. Based on a simplified mass balance equation, the average emission rates of particle number, PM 2.5 and O 3 were calculated. The results showed that: almost all printers were found to be high particle number emitters (i.e. > 1.01×10 10 particles/min); colour printing generated more PM 2.5 than monochrome printing; and all printers generated significant amounts of O 3 .Particle number emissions varied significantly during printing and followed the cycle of fuser roller temperature variation, which points to temperature being the strongest factor controlling emissions. For two sub-groups of printers using the same technology (heating lamps), systematic positive correlations, in the form of a power law, were found between average particle number emission rate and average roller temperature.Other factors, such as fuser material and structure, are also thought to play a role, since no such correlation was found for the remaining two sub-groups of printers using heating lamps, or for the printers using heating strips. In addition, O 3 and total PM 2.5were not found to be statistically correlated with fuser temperature.
While recent research has provided valuable information as to the composition of laser printer particles, their formation mechanisms, and explained why some printers are emitters while others are low emitters, questions relating to the potential exposure of office workers remained unanswered. In particular, (i) what impact does the operation of laser printers have on the background particle number concentration (PNC) of an office environment over the duration of a typical working day? (ii) What is the airborne particle exposure to office workers in the vicinity of laser printers? (iii) What influence does the office ventilation have upon the transport and concentration of particles? (iv) Is there a need to control the generation of, and/or transport of particles arising from the operation of laser printers within an office environment? (v) What instrumentation and methodology is relevant for characterizing such particles within an office location? We present experimental evidence on printer temporal and spatial PNC during the operation of 107 laser printers within open plan offices of five buildings. The 8 h time-weighted average printer particle exposure is significantly less than the 8 h time-weighted local background particle exposure, but that peak printer particle exposure can be greater than 2 orders of magnitude higher than local background particle exposure. The particle size range is predominantly ultrafine (<100 nm diameter). In addition we have established that office workers are constantly exposed to nonprinter derived particle concentrations, with up to an order of magnitude difference in such exposure among offices, and propose that such exposure be controlled along with exposure to printer derived particles. We also propose, for the first time, that peak particle reference values be calculated for each office area analogous to the criteria used in Australia and elsewhere for evaluating exposure excursion above occupational hazardous chemical exposure standards. A universal peak particle reference value of 2.0 × 10(4) particles cm(-3) has been proposed.
Intravascular optical coherence tomography (IVOCT) is a well-established method for the high-resolution investigation of atherosclerosis in vivo. Intravascular near-infrared fluorescence (NIRF) imaging is a novel technique for the assessment of molecular processes associated with coronary artery disease. Integration of NIRF and IVOCT technology in a single catheter provides the capability to simultaneously obtain co-localized anatomical and molecular information from the artery wall. Since NIRF signal intensity attenuates as a function of imaging catheter distance to the vessel wall, the generation of quantitative NIRF data requires an accurate measurement of the vessel wall in IVOCT images. Given that dual modality, intravascular OCT-NIRF systems acquire data at a very high frame-rate (>100 frames/second), a high number of images per pullback need to be analyzed, making manual processing of OCT-NIRF data extremely time consuming. To overcome this limitation, we developed an algorithm for the automatic distance-correction of dual-modality OCT-NIRF images. We validated this method by comparing automatic to manual segmentation results in 180 in vivo images from 6 New Zealand White rabbit atherosclerotic after indocyanine-green (ICG) injection. A high Dice similarity coefficient was found (0.97 ± 0.03) together with an average individual A-line error of 22 μm (i.e., approximately twice the axial resolution of IVOCT) and a processing time of 44 ms per image. In a similar manner, the algorithm was validated using 120 IVOCT clinical images from 8 different in vivo pullbacks in human coronary arteries. The results suggest that the proposed algorithm enables fully automatic visualization of dual modality OCT-NIRF pullbacks, and provides an accurate and efficient calibration of NIRF data for quantification of the molecular agent in the atherosclerotic vessel wall.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.