Rotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved a 11% and 3.5% reduction in stalling mass flow respectively, with injection adding 3.6% of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip, of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the pre-stall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the pre-stall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately 10 rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150% of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes which comprise the first three harmonic perturbations in this transonic region of operation.
This paper presents the first attempt to stabilize rotating stall in a single-stage transonic axial flow compressor with inlet distortion using active feedback control. The experiments were conducted at the NASA Lewis Research Center on a single-stage transonic core compressor inlet stage. An array of 12 jet injectors located upstream of
This paper presents the first attempt to stabilize rotating stall in a single-stage transonic axial flow compressor with inlet distortion using active feedback control. The experiments were conducted at the NASA Lewis Research Center on a single-stage transonic core compressor inlet stage. An annular array of 12 jet-injectors located upstream of the rotor tip was used for forced response testing and to extend the compressor stable operating range. Results for radial distortion are reported in this paper. First, the effects of radial distortion on the compressor performance and the dynamic behavior were investigated. Control laws were designed using empirical transfer function estimates determined from forced response results. The transfer functions indicated that the compressor dynamics are decoupled with radial inlet distortion, as they are for the case of undistorted inlet flow. Single-input-single-output (SISO) control strategies were therefore used for the radial distortion controller designs. Steady axisymmetric injection of 4 percent of the compressor mass flow resulted in a reduction in stalling mass flow of 9.7 percent relative to the case with inlet distortion and no injection. Use of a robust H∞ controller with unsteady nonaxisymmetric injection achieved a further reduction in stalling mass flow of 7.5 percent, resulting in a total reduction of 17.2 percent.
This paper presents the first attempt to stabilize rotating stall in a single-stage transonic axial flow compressor with inlet distortion using active feedback control. The experiments were conducted at the NASA Lewis Research Center on a single-stage transonic core compressor inlet stage. An annular array of 12 jet-injectors located upstream of the rotor tip was used for forced response testing and to extend the compressor stable operating range. Results for radial distortion are reported in this paper. First, the effects of radial distortion on the compressor performance and the dynamic behavior were investigated. Control laws were designed using empirical transfer function estimates determined from forced response results. The transfer functions indicated that the compressor dynamics are decoupled with radial inlet distortion, as they are for the case of undistorted inlet flow. Single-input-single-output (SISO) control strategies were therefore used for the radial distortion controller designs. Steady axisymmetric injection of 4% of the compressor mass flow resulted in a reduction in stalling mass flow of 9.7% relative to the case with inlet distortion and no injection. Use of a robust H∞ controller with unsteady non-axisymmetric injection achieved a further reduction in stalling mass flow of 7.5%, resulting in a total reduction of 17.2%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.