Formation of hydrates is a well known problem in subsea production systems for oil and gas. As the unprocessed well-stream cools down, hydrates are formed at temperatures up to 250C depending on the water cut and pressure inside the pipeline. Several options are available to
Overheating of metallic ground screen connections at accessories of single core cables are the root cause of severe insulation failures in the distribution network. The overheating is due to a high transition resistance of the connections combined with high induced currents in the ground screens during operation. For copper screened cables equipped with a metallic laminate, overheating causing failures are also observed randomly along the cables often at locations close to cable straps or cleats. Currently there are no international standards with complete tests to determine the ampacity of ground screen connections for different cable system designs making future installations more reliable. Furthermore, product information from the suppliers indicates that basis for design and test criteria is not uniform, and tests are not performed concerning relevant operation and fault scenarios. A research project is launched in Norway, to test different ground screen connections and then to provide guidelines to ensure proper future installations. A new CIRED working group is proposed to provide recommendations for complete tests of ground screen connections lacking in current international standards and brochures.
Traditional chemical treatment methods have considerable operation costs and represent a risk to the environment. Since 1987 Norwegian oil companies have been investigating alternative electrical heating methods for prevention of hydrate and wax plugs. A joint industry project ‘Concept Verification – Direct Heating of Oil & Gas Pipelines’ was initiated in 1996 and terminated in October 1999. During this work an electrical heating system was proved to be feasible on several fields in the North Sea. It will be installed on 7 flowlines of 13% Chromium (Crl3) with lengths between 6 km and 16 km. Electrical heating is used to maintain or raise the thermally insulated steel pipe temperature above the critical value for hydrate formation (typically 15–25 °C) or wax formation (typically 20–40°C). A single-phase power supply for the heating system is based on commercial components and connected to the platform power supply. The qualification work for the direct heating system has included full scale testing for single and parallel pipes, end termination at the template, bypass of a template and aspects concerning corrosion control. The rating of the system is dependent on the magnetic and electrical characteristics of the steel material. Such data is not commonly available. Measurements performed during the qualification program confirm that the magnetic characteristic may vary within a wide range for a specific steel quality and that mechanical stress and heat treatment can effect the magnetic characteristic. The difference in magnetic characteristic of individual Crl3 pipes results in variation of the pipe temperature and problems concerning differential pressure during melting. The problem can be handled by dividing the pipeline into a number of sections, each with a limited variation of the magnetic characteristic, thus keeping the temperature for the whole pipeline within acceptable limits. As a part of the pipe specification both electrical and magnetic characteristic should be available. These data can be determined by measuring arrangements in the production line of the mill. Measures to limit the variation of magnetic characteristic should be discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.