Background To report sampling of the trabecular meshwork using the TrabEx+ (MicroSurgical Technology, Redmond, Washington, USA) device in ab interno trabeculectomy. Specifically, this series focusses upon preservation of the trabecular meshwork architecture for assessment of glaucomatous features using common histopathological techniques. Patients This series features six glaucomatous eyes undergoing TrabEx+ with or without cataract surgery. Three patients had primary open angle glaucoma and the remaining had pigment dispersion glaucoma, ocular hypertension or uveitic glaucoma. Four eyes had simultaneous cataract surgery. Methods Trabecular meshwork was excised using the TrabEx+ device and retrieved using vitreoretinal forceps. The samples were then processed into formalin-fixed paraffin-embedded 4 micron tissue segments and stained with haematoxylin and eosin, periodic acid–Schiff and elastin Van Gieson. Collagen IV was labelled using immunohistochemistry for the purpose of identifying the basement membrane of trabecular beams. Results Presence of trabecular meshwork was confirmed in five of the six samples taken. One of six samples consisted of blood only, but this was expected following early termination of the procedure due to patient restlessness. In the five positive cases trabecular beams with associated trabecular meshwork cells were identified on hematoxylin-eosin and periodic acid–Schiff staining. The beams retained their lamellar structure. The basement membrane underlying the trabecular cells was evident in three specimens, whilst two specimens were of insufficient size for collagen IV labelling. Conclusions This case series illustrates that TrabEx+ can be utilised to successfully retrieve trabecular meshwork samples with sufficient architectural perseveration of the tissue to enable histopathological and laboratory analysis.
BackgroundPulmonary hypoplasia, Diaphragmatic anomalies, Anophthalmia/microphthalmia and Cardiac defects delineate the PDAC syndrome. We aim to identify the cause of PDAC syndrome in patients who do not carry pathogenic variants inRARBandSTRA6, which have been previously associated with this disorder.MethodsWe sequenced the exome of patients with unexplained PDAC syndrome and performed functional validation of candidate variants.ResultsWe identified bi-allelic variants inWNT7Bin fetuses with PDAC syndrome from two unrelated families. In one family, the fetus was homozygous for the c.292C>T (p.(Arg98*)) variant whereas the fetuses from the other family were compound heterozygous for the variants c.225C>G (p.(Tyr75*)) and c.562G>A (p.(Gly188Ser)). Finally, a molecular autopsy by proxy in a consanguineous couple that lost two babies due to lung hypoplasia revealed that both parents carry the p.(Arg98*) variant. Using a WNT signalling canonical luciferase assay, we demonstrated that the identified variants are deleterious. In addition, we found thatwnt7bbmutant zebrafish display a defect of the swimbladder, an air-filled organ that is a structural homolog of the mammalian lung, suggesting that the function of WNT7B has been conserved during evolution for the development of these structures.ConclusionOur findings indicate that defective WNT7B function underlies a form of lung hypoplasia that is associated with the PDAC syndrome, and provide evidence for involvement of the WNT–β-catenin pathway in human lung, tracheal, ocular, cardiac, and renal development.
Background: MIRAgel® (MIRA, Waltham, MA, USA) is a hydrogel scleral buckle introduced in 1979 to treat rhegmatogenous retinal detachments. Its use was discontinued because late complications that require surgical removal were reported. Methods: Case report. Results: We report a case of left eye MIRAgel® buckle surgery 28 years ago presenting with a tender palpable erythematous swelling at the lower lid, with marked conjunctival chemosis and progressive ophthalmoplegia. Imaging revealed a large, well-defined, horseshoe-shaped lesion in the extraconal space of the left orbit with globe distortion, with histological confirmation of an expanded hydrogel buckle. He recovered well following removal of the explant but developed chronic macular oedema a year later, which persisted despite sub-Tenon’s triamcinolone injections. Repeat imaging demonstrated remaining hydrogel explant. Macular oedema settled well upon successful surgical removal with no recurrence to date. Conclusion: Our case is the first to describe macular oedema as a late MIRAgel-related complication, with complete removal of the explant being the definitive treatment. Macular oedema indicates postoperative inflammation secondary to the remaining explant fragments. Given the friability of hydrolysed MIRAgel®, we recommend ophthalmologists to warn patients regarding the possibility of further inflammation in the globe or the orbit in case of incomplete removal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.