Among patients with a recent cryptogenic stroke or TIA who were 55 years of age or older, paroxysmal atrial fibrillation was common. Noninvasive ambulatory ECG monitoring for a target of 30 days significantly improved the detection of atrial fibrillation by a factor of more than five and nearly doubled the rate of anticoagulant treatment, as compared with the standard practice of short-duration ECG monitoring. (Funded by the Canadian Stroke Network and others; EMBRACE ClinicalTrials.gov number, NCT00846924.).
Background and Purpose— Many ischemic strokes or transient ischemic attacks are labeled cryptogenic but may have undetected atrial fibrillation (AF). We sought to identify those most likely to have subclinical AF. Methods— We prospectively studied patients with cryptogenic stroke or transient ischemic attack aged ≥55 years in sinus rhythm, without known AF, enrolled in the intervention arm of the 30 Day Event Monitoring Belt for Recording Atrial Fibrillation After a Cerebral Ischemic Event (EMBRACE) trial. Participants underwent baseline 24-hour Holter ECG poststroke; if AF was not detected, they were randomly assigned to 30-day ECG monitoring with an AF auto-detect external loop recorder. Multivariable logistic regression assessed the association between baseline variables (Holter-detected atrial premature beats [APBs], runs of atrial tachycardia, age, and left atrial enlargement) and subsequent AF detection. Results— Among 237 participants, the median baseline Holter APB count/24 h was 629 (interquartile range, 142–1973) among those who subsequently had AF detected versus 45 (interquartile range, 14–250) in those without AF ( P <0.001). APB count was the only significant predictor of AF detection by 30-day ECG ( P <0.0001), and at 90 days ( P =0.0017) and 2 years ( P =0.0027). Compared with the 16% overall 90-day AF detection rate, the probability of AF increased from <9% among patients with <100 APBs/24 h to 9% to 24% in those with 100 to 499 APBs/24 h, 25% to 37% with 500 to 999 APBs/24 h, 37% to 40% with 1000 to 1499 APBs/24 h, and 40% beyond 1500 APBs/24 h. Conclusions— Among older cryptogenic stroke or transient ischemic attack patients, the number of APBs on a routine 24-hour Holter ECG was a strong dose-dependent independent predictor of prevalent subclinical AF. Those with frequent APBs have a high probability of AF and represent ideal candidates for prolonged ECG monitoring for AF detection. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00846924.
BackgroundThe PulsePoint Respond app is a novel system that can be implemented in emergency dispatch centers to crowdsource basic life support (BLS) for patients with cardiac arrest and facilitate bystander cardiopulmonary resuscitation (CPR) and automated external defibrillator use while first responders are en route.ObjectiveThe aim of this study was to conduct a North American survey to evaluate the public perception of the above-mentioned strategy, including acceptability and willingness to respond to alerts.MethodsWe designed a Web-based survey administered by IPSOS Reid, an established external polling vendor. Sampling was designed to ensure broad representation using recent census statistics.ResultsA total of 2415 survey responses were analyzed (1106 from Canada and 1309 from the United States). It was found that 98.37% (1088/1106) of Canadians and 96% (1259/1309) of Americans had no objections to PulsePoint being implemented in their community; 84.27% (932/1106) of Canadians and 55.61% (728/1309) of Americans said they would download the app to become a potential responder to cardiac arrest, respectively. Among Canadians, those who said they were likely to download PulsePoint were also more likely to have ever had CPR training (OR 1.7, 95% CI 1.2-2.4; P=.002); however, this was not true of American respondents (OR 1.0, 95% CI 0.79-1.3; P=.88). When asked to imagine themselves as a cardiac arrest victim, 95.39% (1055/1106) of Canadians and 92.44% (1210/1309) of Americans had no objections to receiving crowdsourced help in a public setting; 88.79% (982/1106) of Canadians and 84.87% (1111/1309) of Americans also had no objections to receiving help in a private setting, respectively. The most common concern identified with respect to PulsePoint implementation was a responder’s lack of ability, training, or access to proper equipment in a public setting.ConclusionsThe North American public finds the concept of crowdsourcing BLS for out-of-hospital cardiac arrest to be acceptable. It demonstrates willingness to respond to PulsePoint CPR notifications and to accept help from others alerted by the app if they themselves suffered a cardiac arrest.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.