We report a high-resolution fiber optic temperature sensor system based on an air-filled Fabry–Pérot (FP) cavity, whose spectral fringes shift due to a precise pressure variation in the cavity. The absolute temperature can be deduced from the spectral shift and the pressure variation. For fabrication, a fused-silica tube is spliced with a single-mode fiber at one end and a side-hole fiber at the other to form the FP cavity. The pressure in the cavity can be changed by passing air through the side-hole fiber, causing the spectral shift. We analyzed the effect of sensor wavelength resolution and pressure fluctuation on the temperature measurement resolution. A computer-controlled pressure system and sensor interrogation system were developed with miniaturized instruments for the system operation. Experimental results show that the sensor had a high wavelength resolution (<0.2 pm) with minimal pressure fluctuation (~0.015 kPa), resulting in high-resolution (±0.32 ℃) temperature measurement. It shows good stability from the thermal cycle testing with the maximum testing temperature reaching 800 ℃.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.