Objective: The long-term durability of transcatheter aortic bioprosthetic valves continues to be a major concern. Standardized criteria of the structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) have recently been defined. Limited studies have evaluated the longterm durability of transcatheter aortic valve implantation (TAVI) according to these new definitions. We aim to analyze the durability of TAVI beyond 5 years and to report the frequency of SVD and BVF. Methods: A total of 89 patients who had undergone TAVI and had theoretically completed at least 5 years after the procedure were included. Either a Medtronic CoreValve or an Edwards SAPIEN XT valve were implanted in the patients. New standardized definitions were used to evaluate SVD and BVF. Results: The mean age of the patients was 78.70±6.95 years. SVD occured in 4 (4.5%) patients during 6 years of follow-up. Severe SVD was observed in 2 patients (2.2%), and these patients had the New York Heart Association class II symptoms. Both patients with severe SVD also met the criteria of BVF. Moderate SVD was observed in 2 patients (2.2%), and these patients had no valve-related symptoms. Of the 4 SVD cases, 2 were associated with increased mean transaortic gradients, whereas the remaining 2 cases were associated with intraprosthetic aortic regurgitation. All patients with SVD are still alive, and none of them have required aortic valve reintervention. Conclusion: Although first-generation TAVI devices were used, we determined the low rate of SVD and BVF at the 6-year follow-up. It may be suggested that there is no major concern associated with TAVI even with first-generation devices regarding long-term durability.
This study aimed to determine the fear of COVID-19 and the quality of life of patients with transcatheter aortic valve implantation (TAVI) during the pandemic. This descriptive cross-sectional study included 132 TAVI patients. Data were collected using a patient information form, the Fear of COVID-19 Scale (FCV-19S), and the EuroQol-5 Dimension (EQ-5D). The mean FCV-19S score of the patients was 17.37 ± 6.12. The mean EQ-5D index score was 0.56 ± 0.37 and the mean VAS score was 65.5 ± 11.5. As per the dimensions of the EQ-5D index, 75% of the patients had mobility problems. According to the logistic regression analysis results, mobility was the most affected parameter, as demonstrated by the worsening in symptoms during the pandemic (odds ratio: 7.370, 95% CI [2.183, 24.881]). The patients with TAVI had a moderate level of fear associated with COVID-19, and the pandemic negatively affected their quality of life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.