Pneumatic tube systems (PTS) present a convenient way for blood sample transport in medical facilities. Associated preanalytical interference in various tests is largely unknown. Implementing point-of-care coagulation management at our institution, we investigated multiple electrode aggregometry (MEA) and rotational thromboelastometry (ROTEM) after PTS transportation. Whole blood samples from patients undergoing general or trauma surgery were analysed by MEA after collection (baseline, '0 × PTS') and sent on a predefined PTS track (n = 12). MEA was repeated after samples travelled the track 4 ('4 × PTS'), 8 ('8 × PTS') and 12 times ('12 × PTS') and compared with stationary controls analysed at the same time. Samples for ROTEM (n = 6) were analysed after collection and travelling the track 12 times. An acceleration detector recorded g-forces on the PTS track. At '0 × PTS' no significant differences in MEA results were detected. Values were significantly lower for transported samples compared with controls ('4 × PTS' to '12 × PTS', p < 0.001). Furthermore, MEA results of PTS samples were significantly decreased for '4 × PTS' to '12 × PTS' compared to baseline (p < 0.001). Except for the clotting time in EXTEM PTS transport did not significantly alter results for investigated ROTEM parameters, compared with baseline and stationary controls. Acceleration detector readout revealed alternating g-forces between -6.3 and +5.9 during transport. PTS transport caused invalid results in MEA while only one ROTEM parameter was found to be affected in this study. Variable acceleration during transport provides a potential reason for platelet activation. The authors recommend sample transport by hand or the device to be placed patient-side when MEA is performed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.