ENB shows an acceptable diagnostic yield with an excellent safety profile in the diagnosis of pulmonary lesions. The use of fluoroscopy and general anesthesia may improve the diagnostic yield.
In our patients admitted to the medical ICU with septic shock, noninvasive blood pressure monitoring did not clinically correlate with invasive blood pressure measurements.
To determine the equivalency of pressure measurements from peripherally inserted central catheters(PICCs) versus centrally inserted central venous catheters(CVCs) in vitro as well as in vivo. The in vitro study was performed in a clinical laboratory. Static pressure measurements from PICCs and CVCs were obtained in vitro over a physiologic range of 5–25 mmHg. Triple and dual lumen PICCs were directly compared to CVC controls.Dynamic pressure waveforms were recorded to simulate physiologic intravascular pressure variation. The in vivo study was executed in the medical intensive care unit(MICU) of a tertiary-level academic medical center. Data was collected from ten adult patients with both a PICC and a CVC in place for on-going clinical care. Measurements of central venous pressure (CVP) were recorded simultaneously from PICCs and CVCs. Duplicate measurements were taken after a stable waveform was recorded. For the in vitro study, a total of 540 pressure measurements were recorded. The average bias determined by Bland–Altman plot was 0 mmHg for the 5Fr PICC and 0.071 mmHg for the 6Fr PICC. The correlation coefficient for both catheters was 1.0 (P<0.001). Dynamic pressure waveforms revealed equivalent amplitude. During the in vivo trial, 70CVP measurements were collected. The paired CVP measurements were found to be highly reliable across subjects (r = 0.99, P<0.0001). No significance in the average difference in CVP measurement (PICC–CVC) was determined by the Wilcoxon Signed Rank test (S = 1,P = 0.93). In conclusion, PICCs are equivalent to CVCs when measuring static and dynamic pressure in vitro and CVP in ICU patients.
BackgroundEarly goal directed therapy improves survival in patients with septic shock. Central venous pressure (CVP) monitoring is essential to guide adequate resuscitation. Use of peripherally inserted central catheters (PICC) is increasing, but little data exists comparing a PICC to a conventional CVP catheter. We studied the accuracy of a novel PICC to transmit static and dynamic pressures in vitro.MethodsWe designed a device to generate controlled pressures via a column of water allowing simultaneous measurements from a PICC and a standard triple lumen catheter. Digital transducers were used to obtain all pressure readings. Measurements of static pressures over a physiologic range were recorded using 5Fr and 6Fr dual lumen PICCs. Additionally, random repetitive pressure pulses were applied to the column of water to simulate physiologic intravascular pressure variations. The resultant PICC and control waveforms were recorded simultaneously.ResultsSix-hundred thirty measurements were made using the 5 Fr and 6 Fr PICCs. The average bias determined by Bland-Altman plot was 0.043 mmHg for 5 Fr PICC and 0.023 mmHg for 6 Fr PICC with a difference range of 1.0 to -1.0. The correlation coefficient for both catheters was 1.0 (p-value < 0.001). Dynamic pressure waveforms plotted simultaneously between PICC and control revealed equal peaks and troughs.ConclusionIn vitro, no static or dynamic pressure differences were found between the PICC and a conventional CVP catheter. Clinical studies are required to assess whether the novel PICC has bedside equivalence to conventional catheters when measuring central venous pressures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.