The evaluation of monocytes recruited into the alveolar space under both physiological and inflammatory conditions is hampered by difficulties in discriminating these cells from resident alveolar macrophages (rAMs). Using the intravenous injected fluorescent dye PKH26, which accumulated in rAMs without labeling blood leukocytes, we developed a technique that permits the identification, isolation, and functional analysis of monocytes recruited into lung alveoli of mice. Alveolar deposition of murine JE, the homologue of human monocyte chemoattractant protein (MCP)-1 (JE/MCP-1), in mice provoked an alveolar influx of monocytes that were recovered by bronchoalveolar lavage and separated from PKH26-stained rAMs by flow cytometry. Alveolar recruited monocytes showed a blood monocytic phenotype as assessed by cell surface expression of F4/80, CD11a, CD11b, CD18, CD49d, and CD62L. In contrast, CD14 was markedly upregulated on alveolar recruited monocytes together with increased tumor necrosis factor-alpha message, discriminating this monocyte population from peripheral blood monocytes and rAMs. Thus monocytes recruited into the alveolar air space of mice in response to JE/MCP-1 keep phenotypic features of blood monocytes but upregulate CD14 and are "primed" for enhanced responsiveness to endotoxin with increased cytokine expression.
The functional activity of von Willebrand factor (VWF) is most frequently measured by using the ristocetin cofactor assay (VWF:RCo). However, the method's drawbacks include unsatisfactory precision, sensitivity and availability of automated system applications. We have developed an alternative assay (INNOVANCE VWF Ac) that is based on the binding of VWF to recombinant glycoprotein Ib (GPIb). Two gain-of-function mutations were introduced into a GPIb fragment, allowing an assay format without ristocetin. Fully automated assay applications are available for the BCS/BCS XP systems and the Sysmex CS-2000i, Sysmex CA-7000, Sysmex CA-1500 and Sysmex CA-560 systems.The INNOVANCE VWF Ac assay measuring range extends from 4 to 600% VWF for all systems except the Sysmex CA-560 system. Within-device precision values were found to be between 2 and 7%. The limit of detection was below 2.2% VWF. In a study on the BCS XP system, a total number of 580 sample results yielded a correlation to the VWF:RCo assay of r equal to 0.99 (slope = 0.96). Very similar results were observed when von Willebrand disease samples type 1, 2A, 2B, 2M, 2N and 3 were investigated with the new assay and the VWF:RCo assay. The excellent performance data and comparability to VWF:RCo, together with the ease of use, led us to the conclusion that the ristocetin cofactor assay can be replaced by the new GPIb-binding assay to reliably diagnosing patients with von Willebrand disease.
Both AP-1 and STAT-1 dODN treatments suppress graft endothelial adhesion molecule expression, reduce graft infiltration and in turn significantly delay acute rejection. The utilization of dODNs in the cardioplegic solution might be a novel strategy to protect transplanted organs from early damage during transplantation, to preserve organ function and bridge the critical phase after transplantation when standard immunosuppression is not yet completely effective.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.