SIGNIFICANCE Increasing prevalence of refractive error requires assessment of ametropia as a screening tool in children. If cycloplegia is not an option, knowledge about the increase in uncertainty for wavefront-based autorefraction is needed. The cycloplegic agent as the principal variant presents cross-reference and allows for extraction of the influence of accommodation. PURPOSE The purpose of this study was to determine the repeatability, agreement, and propensity to accommodate of cycloplegic (ARc) and noncycloplegic (ARnc) wavefront-based autorefraction (ZEISS i.Profiler plus; Carl Zeiss Vision, Aalen, Germany) in children aged 2 to 15 years. METHODS In a clinical setting, three consecutive measurements were feasible for 145 eyes (OD) under both conditions. Data are described by spherical equivalent (M), horizontal or vertical astigmatic component (J0), and oblique astigmatic component (J45). In the case of M, the most positive value of the three measurements was chosen, whereas the mean was applied for astigmatic components. RESULTS Regarding agreement, differences for ARc minus ARnc were statistically significant: for M, 0.55 (0.55 D; mean [SD]; P < .001), that is, more hyperopic in cycloplegia; for J0, −0.03 (0.11 D; P = .002); and for J45, −0.03 D (SD, 0.09 D; P < .001). Regarding repeatability, astigmatic components showed excellent repeatability: SD < 0.11 D (ARnc) and SD < 0.09 D (ARc). The repeatability of M was SD = 0.57 D with a 95% interval of 1.49 D (ARnc). Under cycloplegia, this decreased to SD = 0.17 D (ARc) with a 95% interval of 0.50 D. The mean propensity to accommodate was 0.44 D from repeated measurements; in cycloplegia, this was reduced to 0.19 D. CONCLUSIONS Wavefront-based refraction measurement results are highly repeatable and precise for astigmatic components. Noncycloplegic measurements of M show a systematic bias of 0.55 D. Cycloplegia reduces the propensity to accommodate by a factor of 2.4; for noncycloplegic repeated measurements, accommodation is controlled to a total interval of 1.49 D (95%). Without cycloplegia, results improve drastically when measurements are repeated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.