We measured the elevation angle distribution and cross-polarization power ratio of the incident power at the mobile station in different radio propagation environments at 2.15-GHz frequency. A novel measurement technique was utilized, based on a wide-band channel sounder and a spherical dual-polarized antenna array at the receiver. Data were collected over 9 km of continuous measurement routes, both indoor and outdoor. Our results show that in non-line-of-sight situations, the power distribution in elevation has a shape of a double-sided exponential function, with different slopes on the negative and positive sides of the peak. The slopes and the peak elevation angle depend on the environment and base-station antenna height. The cross-polarization power ratio varied within 6.6 and 11.4 dB, being lowest for indoor and highest for urban microcell environments. We applied the experimental data for analysis of the mean effective gain (MEG) of several mobile handset antenna configurations, with and without the user's head. The obtained MEG values varied from approximately 5 dBi in free space to less than 11 dBi beside the head model. These values are considerably lower than what is typically used in system specifications. The result shows that considering only the maximum gain or total efficiency of the antenna is not enough to describe its performance in practical operating conditions. For most antennas, the environment type has little effect on the MEG, but clear differences exist between antennas. The effect of the user's head on the MEG depends on the antenna type and on which side of the head the user holds the handset. Index Terms-Angular power distribution, mean effective gain, mobile antenna, polarization, radio channel sounding. I. INTRODUCTION T HE gain of a mobile handset antenna is a critical parameter in cellular network design. Due to the large variety of mobile phones used in networks, it is very important that their antenna performance be able to be evaluated reliably. The traditional definition of antenna gain is not adequate for evaluating Manuscript
Parvovirus B19 causes a variety of diseases in humans, with outcomes ranging from asymptomatic to severe, such as chronic anemia in immunocompromised patients or fetal hydrops and death after maternal infection during pregnancy. The virus may be transmitted via plasma-derived products. According to the results of solventdetergent safety studies, an upper limit of B19 DNA in plasma pools was recently defined. To restrict the input of B19 virus into production pools, a quantitative nucleic acid test is a prerequisite. We examined the suitability of the two commercial quantitative B19 PCR tests, LightCycler-Parvovirus B19 quantification kit (Roche Diagnostics) and RealArt Parvo B19 LC PCR (Artus) for detection, quantification, and differentiation of the three known B19 genotypes, including the newly described erythrovirus variants (genotypes 2 and 3). The former kit was highly sensitive for genotype 1 but was not suitable for detection of genotype 2 or one of two genotype 3 strains. The latter kit detected and differentiated all three genotypes, albeit with lower sensitivity for one of the genotype-3 strains. We furthermore assessed the prevalence of the three B19 virus genotypes in blood donors, by screening pooled plasma samples derived from 140,160 Finnish blood-donor units. None of the pools contained detectable levels of B19 virus genotypes 2 or 3. The origin, mode of transmission, and clinical significance of these genotypes are unknown and deserve further study. The RealArt Parvo B19 LC PCR is suitable for detection, quantification, and differentiation of all three B19 virus genotypes in molecular and clinical research.
BACKGROUND External quality assessment (EQA) with commutable samples is essential for assessing the quality of assays performed by laboratories, particularly when the emphasis is on their standardization status and interchangeability of results. METHODS We used a panel of 20 fresh-frozen single-donation serum samples to assess assays for the measurement of creatinine, glucose, phosphate, uric acid, total cholesterol, HDL cholesterol, LDL cholesterol, and triglycerides. The commercial random access platforms included: Abbott Architect, Beckman Coulter AU, Ortho Vitros, Roche Cobas, Siemens Advia, and Thermo Scientific Konelab. The assessment was done at the peer group level and by comparison against the all-method trimmed mean or reference method values, where available. The considered quality indicators were intraassay imprecision, combined imprecision (including sample–matrix interference), bias, and total error. Fail/pass decisions were based on limits reflecting state-of-the-art performance, but also limits related to biological variation. RESULTS Most assays showed excellent peer performance attributes, except for HDL- and LDL cholesterol. Cases in which individual assays had biases exceeding the used limits were the Siemens Advia creatinine (−4.2%), Ortho Vitros phosphate (8.9%), Beckman Coulter AU triglycerides (5.4%), and Thermo Scientific Konelab uric acid (6.4%), which lead to considerable interassay discrepancies. Additionally, large laboratory effects were observed that caused interlaboratory differences of >30%. CONCLUSIONS The design of the EQA study was well suited for monitoring different quality attributes of assays performed in daily laboratory practice. There is a need for improvement, even for simple clinical chemistry analytes. In particular, the interchangeability of results remains jeopardized both by assay standardization issues and individual laboratory effects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.