Precis: Using standard glaucoma structural and functional tests, clinicians accurately predicted the presence/absence of 10-2 glaucomatous visual field (VF) loss in 90% of the eyes in this study.Purpose: To investigate how well clinicians with variable experience can predict the presence and location of 10-2 VF loss using structural and functional data that are routinely obtained for glaucoma assessment.Methods: Within a test set of 416 eyes (210 subjects) who were diagnosed glaucoma suspect or primary open-angle glaucoma (with most eyes having mild disease), 6 clinicians were asked to predict the presence and hemispheric location of 10-2 VF loss using 24-2 VF and spectral-domain optical coherence tomography structural data. Prediction accuracies were calculated for each clinician and compared using the weighted κ-statistic. Receiver operating characteristic analyses were used to evaluate models for predicting 10-2 VF loss.Results: Among the 6 clinicians, mean (range) accuracy, false negatives, and false positives for predicting presence/absence of 10-2 VF loss were 90% (87% to 92%), 4.7% (2.4% to 7.0%), and 5.4% (1.7% to 7.5%) respectively. The mean (range) weighted κ-statistic was 0.75 (0.64 to 0.83), suggesting good or very good inter-rater agreement between examiners. Mean accuracy for correctly predicting hemispheric location was 73% (range, 65% to 82%) with the most common error occurring in eyes with both superior and inferior 10-2 VF defects in which one hemisphere was correctly identified but the other missed.Conclusions: In this study, the presence/absence of 10-2 glaucomatous VF loss was highly predictable using standard functional and structural clinical metrics. These findings suggest that 10-2 VF testing is not needed to reliably recognize and confirm central VF involvement in most eyes with glaucoma. Whether error related to identifying second hemisphere involvement in 10-2 VF loss is important requires further study.
Précis: Presence of baseline 10-2 visual field (VF) loss was the strongest predictor of future rate of 24-2 VF loss and development of new 24-2 progression events, suggesting a role for 10-2 VF testing in baseline glaucoma risk analysis. Purpose:The purpose of this study is to examine the relationship between baseline 10-2 VF loss and future 24-2 VF loss.Materials and Methods: Subjects were participating in a prospective longitudinal study within a VA Medical Center outpatient eye clinic. Eligibility required 2 good quality baseline 10-2 VF tests followed by a minimum of 5 good quality 24-2 VF tests over at least 3 years. Longitudinal 24-2 VF testing was completed every 4-6 months after baseline 10-2 testing. Mixed model regression analyses and Cox Proportional Hazard regression analyses were completed to identify predictors of 24-2 mean deviation change rate and new VF loss events.Results: We studied 394 eyes of 202 subjects (119 primary open angle glaucoma and 83 glaucoma suspect). Over 6.7 ( ± 1.5) years, 9.9 ( ± 2.3) good quality 24-2 VF tests were completed. In mixed model regression analyses, baseline variables that predicted faster rate of 24-2 VF loss in order of strength of association were presence of baseline 10-2 VF defect, lower 24-2 mean deviation, and higher age. When analyses were completed without 10-2 variables, predictive capability of the model was reduced compared with when 10-2 variables were included. In Cox Proportional Regression analyses evaluating progression events, baseline 10-2 VF defect demonstrated the largest hazard ratio (22 times greater risk for developing future VF loss event in eyes with vs. without baseline 10-2 VF loss).Conclusions: Baseline 10-2 VF defect was the most effective predictor of subsequent 24-2 VF progression in this study. These findings imply that presence of baseline 10-2 VF loss may provide unique value for predicting future glaucoma progression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.